Mystery of 60-Second Fluctuations in Power Grids Solved

(fz-juelich.de)

214 points | by _Microft 2 days ago

13 comments

  • andrelaszlo 4 hours ago
    Funny, similar patterns are super common in API traffic. A large spike at midnight UTC, a smaller one every hour, even smaller ones every 15 minutes, and a little bump every minute if your metrics have enough resolution. Of course, if someone calls your API every minute you should probably consider some kind of streaming, or at least include make the request cheap by requiring a cursor of some kind.
    • moebrowne 1 hour ago
      Package managers like apt will delay automatic updates for a random time to avoid this problem:

          RandomizedDelaySec=12hr
      
      https://wiki.debian.org/PeriodicUpdates#Modify_the_schedule_...
    • catlifeonmars 1 hour ago
      > and a little bump every minute if your metrics have enough resolution

      Amusingly, you can also observe periodic bumps if your metrics don’t have enough resolution, due to aliasing effects dominating signal (guestures vaguely at Nyquist frequency).

      • IAmBroom 58 minutes ago
        By definition, if you can see effects then the metrics have enough resolution.

        The specific resolution is the Nyquist frequency - that part is accurate.

        • formerly_proven 48 minutes ago
          Sampling metrics is sampling and leads to aliasing.

          Similarly, sample count/interval limits in tsdbs like prometheus are not downsampling. They're just skipping samples. This also creates aliasing. Can be very noticeable especially if you combine it with rate/derivative functions.

    • pumba_noob 3 hours ago
      Same here. We see this kind of spikes in our tunnel traffic also - every hour and specially at midnight UTC. Cron jobs everywhere :)
  • manarth 8 hours ago
  • schobi 8 hours ago
    The press release is rather light on details. They found that it is every 60seconds (duh!) and generators (or such). So what exactly is it? (Make and model?)

    Seems like they did not find the exact manufacturer or the exact devices and were not able to change firmware then?

    • manarth 8 hours ago
      The paper has a little more details:

        "following our communication with the manufacturer, a software update was issued that removed the strict periodicity of the current peaks in one battery block of the investigated UPS system"
      
      https://www.nature.com/articles/s41560-026-02144-0

      Given the issue is so widespread (international, affecting pretty much every grid), it's likely that multiple manufacturers use similar approaches.

      • hyperman1 5 hours ago
        You see the same thing with e.g. cron jobs, where everyone schedules on xx:00 or xx:30. No communication needed, it's just natural. More senior people recognize this and add randomness to their start times or skew a bit.
        • tetha 4 hours ago
          I always recommend to use weird numbers for different tasks. That way, you can see "oh my system is under severe load at *:13 (or 17, 23, 42, ...). That must be this cron job"
          • catlifeonmars 1 hour ago
            I do a similar thing with ping payload sizes to be able to fingerprint the traffic: I’ll use prime numbered packet sizes so that they can be detected even when the packet sizes are summed.

            Btw, one of those numbers is not like the others (has more prime factors that evenly divide 60).

            • IAmBroom 55 minutes ago
              Good point. 7,11,13... do not repeat every hour.
        • truekonrads 5 hours ago
          You ought to use RandomizedDelaySec=xxx
          • IAmBroom 53 minutes ago
            Depends. If you want a breadcrumb trail, use primes. If you want no noticeable effect at all, or cannot imagine a traffic bump that you'll want to decipher, use random offsets.
        • greggsy 3 hours ago
          It’s entirely possible the battery controllers are running linux too
  • Arn_Thor 3 hours ago
    Excellent sleuthing. Witthaut these fellas we'd still be in the dark
  • qrios 12 hours ago
    • _Microft 11 hours ago
      It had both ended up in the second chance pool.
  • peesem 9 hours ago
    i'm confused, why would a system simply checking its own power state be taking so much electricity as to show up on grid measurements? unless they mean that the systems are choosing to start charging the batteries, but then it's a continuous load and not a spike at the start of the minute, right?
    • ROOFLES 4 hours ago
      The Frequency is actually increasing at every event which means grid load is reduced for a short while every minute. Those UPS installations basically briefly switch to Battery every Minute to test Capacity/internal resistance and so on. This so called "load dump" is visible in grid frequency since a lot of these systems work synchronous thanks to NTP
    • kzrdude 55 minutes ago
      If they are checking the charging at exactly the minute, then start of charge will happen then too, which will create a spike if it's synchronized with many others doing the same thing.
    • theo939eirn 9 hours ago
      It can be that part of battery is disconnected, to estimate cells voltage. You can not measure voltage while another source is chsrging battery. Or capacitors are charging.
      • deepsun 9 hours ago
        I think you can. RC toys do that all the time. Maybe the measurement is less precise, but you usually don't need super precise voltage, especially if you know your capacitance and measure current.
        • LoganDark 6 hours ago
          Current doesn't tell you if the battery is leaking charge, or otherwise failing to store it though. Vastly increased losses could be a sign of failure, for example. In any case it's important to be sure.
          • wolfi1 5 hours ago
            temperature is also a problem
            • LoganDark 4 hours ago
              Temperature probes shouldn't require disconnecting cells, though.
              • wolfi1 3 hours ago
                no the temperature changes the voltage reading
  • Blackarea 11 hours ago
    > It really was years of detective work

    Doesn't seem that complicated from the article though. They say that they immediately knew it was clock based due to the strict interval. With REA etc. it might become easier to proof, but I guess it's a measurement problem that only appears in large networks?

    Can someone with more understanding explain why this was apparently so difficult to find out?

    • myself248 2 hours ago
      When you monitor a power line, you don't get a tcpdump showing who's producing and who's consuming the power. You can't just jump straight to the culprit.

      It's just bulk flows, so when a weird flow shows up, you've got to move up or down the line, past a few producers or consumers, and see if the flow changes. For a subtle effect, that might not even be so clear.

      Worse, for an effect that's most visible at the medium-voltage transmission level, simply placing a monitor might take weeks. These are planned installations with incredible safety considerations -- you don't just plug in.

      Finally they found a research campus with a bunch of battery storage systems, AND the ability to install a bunch of monitors, and persuaded them to install dozens of monitoring points. Finally a high-resolution view of the effect allowed them to confirm the behavior.

    • Animats 7 hours ago
      The effect is apparently small enough that they had to use Fourier analysis over many minutes to see it in the noise.
      • sidewndr46 3 hours ago
        That's not really telling us anything. The way you convert a time domain signal to a frequency domain signal, that is fourier analysis. There are other uses for it too, but that is the primary use.
        • danadam 1 hour ago
          By increasing the length of the FFT you lower the apparent noise floor in the FFT magnitude plot and are able to detect smaller signals. That's called "FFT processing gain". The formula is:

          FFT gain = 10*log(M/2)

          where M is the number of points processed in the FFT. Doubling the number of points, lowers the apparent noise floor by 3 dB.

          (I don't know if that's what the researchers actually did. I'm just explaining what the comment presumably meant.)

    • mschuster91 1 hour ago
      > Can someone with more understanding explain why this was apparently so difficult to find out?

      Because the grid as a whole is dumb as fuck. Sure, you got measurement stations doing very fine frequency analysis, to the point you can use grid hum to timestamp audio recordings [1].

      But you rarely have realtime insight at individual busbar level for each substation or heaven forbid consumers. Best chance you get is 15-minute consumption pings and voltage/frequency metering at large plants.

      That means if you want to track down bad actors like the batteries here or the Kosovo/Serbia bullshit [2] that dragged down the frequency on the entire ENTSO-E grid (which is quite the challenge!), it takes months if not years.

      [1] https://en.wikipedia.org/wiki/Electrical_network_frequency_a...

      [2] https://www.entsoe.eu/news/2018/04/03/frequency-deviations-c...

      • sandos 1 hour ago
        "But you rarely have realtime insight at individual busbar level for each substation"

        This is kind of understandable, the amount of data would be huge. When faults happen though, recordings are automatically made available.

        Some of these measurements can have surprisingly high frequency sampling, even though the grid itself feels "slow".

    • nomel 9 hours ago
      There are many millions of devices connected that draw power, and increasingly so, supply power.
    • sandworm101 3 hours ago
      >> explain why this was apparently so difficult to find out?

      Likely because the source of the noise was a class of energy providers that themselves react to fluctuation in the grid. Electricity may travel at the speed of light but all the little switches and transistors that connect/disconnect suppliers do not. It would have been noise within noise.

      • Y_Y 3 hours ago
        Not quite the speed of light (in a vacuum) if your watching signals propagate along a conductor:

        https://en.wikipedia.org/wiki/Velocity_factor#Typical_veloci...

        • sandworm101 2 hours ago
          Well ya, nothing on earth moves that fast, but the speed of power/signal in a grid is a speed described using direct reference to c, as opposed to the frequency of AC current which is measurable in frequencies we can actually appreciate with our own ears/eyes. They are in different leagues.
    • iofiiiiiiiii 8 hours ago
      If it were not a substantial research effort spanning years, it would not get funded. This motivates academic researchers to ensure that every topic is explored thoroughly and at great length.
  • neuroelectron 54 minutes ago
    It's really surprising to me this took years to solve.
  • pseudohadamard 1 day ago
    The water-hammer effect, or in this case electron-hammer effect, is why you don't reboot every Windows server in the data center at exactly 2am, to stagger the load shift over time. Surprised that the power guys didn't realize that switching a presumably multi-hundred-MW load in and out at the top of each minute would cause a problem.
    • dylan604 11 hours ago
      Sounds like they've been set up as cron tasks. I've always been unhappy with the 1 minute granularity of cron tasks. Only thing I could come up with was putting a sleep(random()) type of line to avoid a thundering herd type of issue.
      • cdot2 20 minutes ago
        By default, systemd timers activate at a random interval within 60 seconds of when the timer is actually set in order to solve that potential issue. It's weird when you set a 60s timer and it activates twice within a few seconds.
      • nlehuen 9 hours ago
        The Google internal equivalent to cron has a ? placeholder in the scheduling spec syntax letting the scheduler deterministically pick an arbitrary valid value within the field range. So ? 2 ... will pick any minute between 02:00 and 02:59 (and I suspect any second within that minute). The value is derived from a hash of the job definition, so overall this spreads the cron load within the hour.

        Obviously cron jobs are not all equal in terms of load and duration, and hours are not all equal in terms of usage, but that still helps prevent trivial spikes similar to the one mentioned in the article (disclaimer: I'm not aware of a recent counterfactual experiment proving this, but that seems a fair assumption).

        • sdenton4 9 hours ago
          I suppose one would end up with checks happening on a random second instead of a random minute - reducing the size of the spike by a factor of 60, but still spiky.
        • Maxion 4 hours ago
          That still lands it at the top of the minute, which is AFAIK the pattern the researchers found.
      • compumike 10 hours ago
        Yes it’s a real effect. I’ve just hardcoded offsets on various jobs:

          * * * * * sleep 17 && …
        
        etc.

        That way I still maintain a per-job 60-second cadence consistently (which random would not), but don’t do it right on the top of the minute.

        • ahoka 5 hours ago
          Yes, using prime numbers are a good way to reduce the risk of multiple timers coinciding, for example a 10s, 30s, 60s period on a freshly restarted node / process.
        • dylan604 10 hours ago
          That's interesting as it is also visible with a crontab -l so that new scripts can avoid using the same second. However, if you have a farm of machines with the same hardcoded value, they will all still stampede at the same time just not at the top of the minute. By allowing a random value, their start times are slightly offset with in the minute. Is the precise 60s consistent interval really that critical or just that each machine checks once per minute-ish?
        • Magniquick 10 hours ago
          Systemd timers do this natively btw, no need to hardcode And imho are also friendlier.
          • Cyph0n 10 hours ago
            But systemd bad :[
            • falserum 6 hours ago
              People slowly are getting used to it. (Less so with journalctl)
          • stonogo 10 hours ago
            BSD cron has supported jitter for decades. This is strictly a linux problem.
            • fch42 3 hours ago
              It's a human problem. Noone "expects" their own "minimal" checks to compound. And everyone (re)implements periodic checks in ever-more-inventive ways. BSD cron solves this ? Alright. Does prometheus use it to schedule its periodic polling ? Do OTel collectors use it to smear their backend metrics uploads ? Does your own code use cron jobs for its "periodic" heartbeating ?

              If the answer to that is all-yes, then my compliments to you. Alas ... at least my experience says that's not how things are done.

      • raverbashing 4 hours ago
        Yeah, and it's not cron, it's "everything running on a digital schedule"

        Analog systems naturally have a dispersion to them, digital ones, especially with everybody on NTP, much less so

    • hobofan 8 hours ago
      It seems more like one or multiple suppliers of battery systems not taking into account that the decentralized deployments of their system could have that effect. If it's not regulated and an open market, this was bound to happen sooner or later.
    • 0xbadcafebee 10 hours ago
      In computer/systems/distributed engineering this is called request smoothing or traffic shaping, and it's implemented by adding jitter, which is a random time offset/pad added to the interval.

      The funny thing is, modern electrical codes already account for this phenomenon. In order to implement Net Metering (selling your power to the grid), modern standards implement two kinds of jitter:

      - Sandia Frequency Shift: a minute shift in the power frequency generated by inverters. If the grid is connected, this is effectively eliminated; if the inverter is disconnected from the grid, it detects the frequency has shifted and disconnects the inverter from the grid.

      - Slip-Mode Frequency Shift: basically the same thing, but phase shift (which I don't understand).

      Both of these are used for anti-islanding (don't create an island of power). When the inverter detects it's isolated and stops outputting current, it then has to check every 5 minutes, with jitter, for whether the grid is restored or not. It has to add random jitter, because otherwise all the mini battery/solar installs will come online at the same time and swamp the grid, causing another outage.

    • metalman 1 day ago
      power guys got surprised as rest of the grid load is human randomised and even huge factories will come on one chonk at a time, vs miilisecond co ordinated load switching at scale, with batteries as the load of the initial surge into even fully charged batteries can be almost infinite, and the whole calculation around grid scale turbines is that they run at very precise rpm's for stability and longevity, but worse, and a big fail, as battery storage is supposed to help with that, not be the problem. bet it gets fixed realy fast as those grid guys definitly get listened to.
      • dylan604 11 hours ago
        > as the load of the initial surge into even fully charged batteries can be almost infinite

        There was an post a couple of days ago about a telco debrief of an interesting outage that happened. Several things went wrong like the audible bell was manually silence from being heard as a step in routine working but was forgotten to put back into normal mode once work was complete. The actual loss in power triggered the automatic switch to the batteries, but something else seemingly benign happened at the same time so that when power was restored, the batteries had been depleted to the point the charging process could not start because of something similar to this. I wish I could remember the write up, as it was really well written about the cascades of failures that occurred.

      • rswail 8 hours ago
        > grid scale turbines is that they run at very precise rpm's for stability and longevity

        The turbines/generators set the grid frequency itself.

        Having the batteries disconnect/connect would cause the generators to slow down and then speed up (or vice versa) which makes the rest of the grid frequency fluctuate as well.

        It may also trigger the FCAS part of the grid that is paid to keep the frequency within the required range which is +/- 10mHz-200mHz.

        https://mainsfrequency.com/frequ_info_en.php

  • SV_BubbleTime 10 hours ago
    >unusually regular

    Oh I’m sure there is a German phrase for this.

    • Jakob 7 hours ago
      I would go with “allzuregelmäßig”.

      Similar to “allzuschön um wahr zu sein”, “allzugroß” etc.

      • donutdonot 6 hours ago
        However this is not a single word, but would be split as "allzu regelmäßig" cf. https://www.korrekturen.de/wortliste/allzuoft.shtml
        • Jakob 4 hours ago
          Oh interesting that got reformed, too! Strange choice to split it in two instead of three words (the latter which would have mimicked English: “all too”).

          Well, then it seems we don’t have any single German word for all too regular anymore :(

          • mkesper 4 hours ago
            This never was one word actually.
            • Jakob 3 hours ago
              Until the reforms in 1996, allzu… was one word: allzuoft, allzuschön, allzugroß, allzuviel, etc. But yeah, probably would have written such a long word in two words even then.

              My new proposal would be überregelmäßig. Über+adjective is still one word only, post-reform. Sounds strange, but grammatically correct, and still conveys the “unusual” part.

    • loehnsberg 6 hours ago
      Not a scholar of languages, but maybe something like "mit unheimlicher Regelmäßigkeit" (with un-home-ly regular-like-ness, read "home" like in "family" -> "familiar").
    • quink 9 hours ago
      Thinking about it tactically, I’ll go with taktisch. :) Takt-isch.
      • wolfi1 5 hours ago
        rather tak-tisch if we are talking hyphenation
      • moi2388 9 hours ago
        Surely you mean Tick-Tacktisch?
      • speakspokespok 6 hours ago
        verdächtig !
    • jgilias 9 hours ago
      uhrwerksmäßig
      • Someone 8 hours ago
        That doesn’t capture the “unusually” in “unusually regular”
        • aa-jv 5 hours ago
          Ungewöhnlichregelmäßig or Hyperregelmäßig works for me, but then there is Regelmäßigkeitsmonsterhaft.

          Still, I think we can push the limits to Bürokratieapokalyptischhyperregelmäßigkeitsgötterungeheuerhaft and feel pretty comfortable with it.

  • yummybrainz 1 day ago
    Thanks for sharing, very cool!
  • snthpy 9 hours ago
    You'd think they'd randomise offsets to avoid a thundering herd effect, like anyone scheduling multiple processes does?
  • vachina 9 hours ago
    > turbines slow down momentarily before accelerating back to their original rotational speed. This increases wear and tear.

    Why though? Due to increased torque?

    • rocqua 5 hours ago
      The grid frequency is set directly by 3 phase generators. So if the grid frequency drops, there is indeed a very strong torque trying to decelerate the turbines.

      To some extent, this is a good thing. Because it means the spinning mass of all turbines in the grid actually provide a buffer for sub-second mismatches in demand and supply. But it does mean that big demand spikes (or drops) put some wear on the systems. They are made for this, but if it gets very periodic it might be more than designed for.

      Note that this means that all turbines in a power network are perfectly synchronized. And if they are not, they are subject to massive torques. This is why a cold start is so hard. You need to bring on generators from one central point to keep everything in sync. And as you bring on new generation capacity you also need to bring on new consumption, that electricity has to go somewhere.

      The reason for this synchronization is because the generators are spinning a magnet past 3 coils, and those coils are directly wired into the power network. If your magnets are out of phase then effectively the entire power network will use those coils to generate a field to get that magnet back in sync. All of those coils on all those generators really are all hard-wired together, it still kind of blows my mind.

    • lnx01 6 hours ago
      Stuxnet damaged gas centrifuges by introducing a subtle change in rotational speed over time, eventually the motors failed mechanically.

      https://en.wikipedia.org/wiki/Stuxnet

    • bajard 7 hours ago
      Because a variation in force is a cycle of stress, which is more destructive than constant force. It's called hysteresis, leading to material fatigue.
    • toomuchtodo 8 hours ago
      When the battery storage systems all temporarily pause providing grid inertia due to the state of charge check they’re performing, grid synchronized spinning mass has to compensate, which slows it down (transferring the kinetic energy to electrical energy), and then is sped back up as battery storage resumes inertia support.

      Broadly speaking, it’s a collective momentum problem. If part of the system inertia sags, another part needs to step in to compensate for the inertia loss, otherwise you have brownouts and eventually, a blackout.

      https://neutrino-energy.com/technology/grid-inertia/

      • EdwardDiego 6 hours ago
        I wish that article wasn't written entirely in Claude speak, it has some useful information, but the obvious AI voice will repel readers.