Once this becomes cheap enough and easy enough, I expect heavy handed regulation pushed by the power companies. Chances are we will buy these, plug it in and our energy bills will be the same or more!
Solar panels are getting cheap enough for grid hook-ups, installation and regulatory approval to become the bottlenecks.
Plug-in solar is suboptimal in many ways, but it does sidestep a lot of those hurdles. Not too surprised to see it on the rise.
Another thing that might be worth keeping in mind is that plug-in solar panels are often installed vertically - i.e. balcony solar. In which case the peak of the panel's generation is offset to the edge of the typical "duck curve". If it gets popular enough to affect the grid, it might get the solar-induced demand slump larger, but make the edges even sharper.
Would that make grid scale battery storage with its instant response even more important?
That’s absolutely crazy, in Australia you could probably get a 30 kW commercial system installed for that. On my house I paid about US$6.5K for a 6.6 kW of panels and a 5 kW inverter, years ago. You’d get the same thing for a bit under US$5K today here.
For the price you’re talking about, you could also get a system with 15 kW of panels with a good 20-30 kWh of battery storage too!
It's the regulation cost that's really hurting us.
Just the required paperwork for the permit in my region cost ~2.5k. structural engineer was 800, architecture diagram was 800, certified electrician stamp on the plans was 800.
Add in the extra cost to facilitate RSD (~5k after mlpe devices, and extra wiring) and tack on the cost for utility interconnection agreements.
Then deal with the NEC requiring UL listed items with no/very little cross certification with things like CE which effectively means you can't buy equipment from China, at least not without a US shop taking a huge markup for branding/certs.
---
Overall, it's just a mess. I walked away from the project (completed, all approved) with a huge dose of skepticism for the permitting/certification/approval process.
This is, as you say, absolutely bananas level of regulation. Here in the UK most panels are "permitted development" (bypass all the local government permitting entirely, as for small sheds and fences etc). There are two utility schemes, one for <3.6kW which costs £30 (G98) and a more complicated one that costs a few hundred £ for larger ones (G99).
"Balcony solar" (<800W) with absolutely zero paperwork (edit: I'm wrong, still needs G99) has just arrived to the UK.
"Plug in solar" (as "Balcony solar" is called in here in the UK) needs G98, not G99 approval and is free for plug in (<8kw). This is just one form to fill out, and the DNO can't refuse approval (assuming you fill out the form). Think of it more as registration than approval.
Current lowest costs from national retailers that I've found (been looking today as it happens!) is City Plumbing - £336 for 475w, £480 for 1050w (panels with 800w max inverter).
Currently in the U.K. they have to have U.K. appeal not just standard eu approval. Hopefully this will be fixed by next year and prices will
Be more reasonable.
Hopefully too regulators will
Change to allow battery
Storage as long as it’s not pore than 800W inverter.
A lot of people in the U.S. are trying to innovate. I think the problem is the fossil fuel industry has been paying government, probably for decades, to implement legal roadblocks at all levels, from individual homes up to states and regions, to non-fossil fuel energy. I think they've also had a hand, at least at the propaganda level, in pushing back on electric vehicles.
Personally, I'd love to see the United States, and the rest of the world, decrease its reliance on oil. We won't get off it in any of our lifetimes, but we should move in that direction. I like diversifying. Any bit helps. Solar in Australia and Arizona. Maybe less so in northern Maine. Wind turbines where there's wind. I personally don't have any aesthetic objection to them. I think they look kind of cool. And certainly better than smokestacks. And so on.
Were there any parts of the process you felt could be reasonably chipped away at through improved beaureaucratic processes or lightweight advocacy?
I've been doing some advocacy work related to balcony solar mostly from a conceptual standpoint but am a renter and don't know much about the actual costs and process behind installing roof panels. I'm curious to know whether there are any low-hanging fruit we could organize around to reduce the regulatory burden on the consumer.
That’s absolutely insane. I just had 5400Wp of panels installed with 15kWh of battery storage and it was ~€12k total. The battery was a bit over half of the costs. That’s the total cost, hardware and labour.
No need for permits for rooftop solar and the only dealings I had with the energy company was filling out an online form to register it. Took maybe 2 minutes.
I just did the same in Norway but without the battery and 12.5 kWp panels for about the same price. Solaredge inverter and some Italian 450W panels.
400V TN 3P grid with export where I am paid spot. Had to fill in a form online that got approved automatically. The energy company (separate from the grid company) automatically detected my export and started deducing the sales of solar from the bill.
The installer had to confirm the installation to the Enova government entity to release my €3k subsidy though.
My family got an fixed three phase setup with a 12kWp, 8 kWh battery (BYD) and a Hybrid Inverter (SMA) alongside a Level 2 22 kW EV charger for a grand total of 16.000€.
My plugin solar setup was a DIY with 1kWp of panels + an 800W inverter and did cost a total of 350€, including the mounting hardware.
Your numbers are way too high. I live in the very expensive San Francisco Bay Area and my system 6kW before federal tax credits was 16k to install in 2021. After credits it was < $12k. I have a friend in Tucson AZ who just paid $12K for a 4kW system with no subsidies.
I did not add a battery because at the time it would have doubled the price. Also, because I have net metering the battery never pays itself off.
The US is getting fleeced! 8 years ago it cost me about $10k AUD to install 6kW. Yes, it came with a $2.8k subsidy but still we are talking about a third.. 8 years ago.. And I paid extra for a Fronius inverter.
Australia pays their tradies higher wages than solar installers in the US, and still has far cheaper costs.
Here's a long podcast episode talking about why it's so much more expensive in the US versus Australia, with a solar expert from Australia that had just added a bunch of C&I solar here in the US:
As an Aussie you should know the American way, pay executives or management absurd amounts and the people who actually get their hands dirty get paid as little as possible.
The far lower costs in Australia are not due to executive pay, it's due to basic efficiency. Americans are doing things in horrendously wasteful ways, because the system is set to act that way, and changing our system of government is too difficult due to political infighting. One of many examples in the article:
> These things are highly optimized that companies will try to do the scheduling so they’re doing two or three jobs on the same street or in the same suburb on the same day, so they don’t have to drive across town to do the second job. If there’s a delay of a couple of days, it’s because they’re trying to make sure that they’re going to do your neighbors at the same time they’re going to do yours. The thing that costs you money in contracting is what they call truck rolls. I believe in the US there’s something like five or six truck rolls per solar installation. In Australia, it’s as few as one or two.
See also the US healthcare system. Or residential building.
It is well known in Australia that you can make a lot of money working as a tradie. Better than software developers do here that's for sure. You are lucky if you can get a tradie to step foot inside your house for less than $200 USD, then the hourly costs start running away pretty quick.
$200 is about the going rate to get somebody to show up in the US as well (DC-metro, specifically). Maybe not for a generic handyman (though that's increasingly true as well), but somebody with a license and training (electrician, plumber).
That's why I installed my 13kw system myself. I saved a ton of money, assuming you don't equate time with money, otherwise it will have cost me a fortune. It was a great learning experience, and quite fun.
Same boat here. I installed my own ground mounted array at double the capacity for half the quoted price from the local installer, even with an electrician coming in to do last mile hookup. Learned a ton. Got a couple fun new tools. Already have my next spot picked out.
In Germany there is no VAT for solar installations - I'm not aware of any other "subsidies".
We (northern part of Germany) installed 7 KW panels with 10 KW battery for €15K in 2024. My neighbor is installing 10 KW panels with 10 KW battery for €18K this week. So it seems the total costs have not dropped any further in the last 2 years.
A lot of the "labor" costs are just regulatory/permitting in disguise. An expedited approval regime with standards such that, permits-wise, installing solar panels was as easy as installing an EV charger would save a ton of money.
I've seen some promising results from solar fences. Because the panels are getting so cheap you can offset the efficiency loss by buying more. Plus, because they are vertical and double sided they get more sunlight earlier and later in the day.
This is significantly more over-built than what you are describing, but there is a company building along this idea[0]. Trailer you can drag to location, unfurl the solar panels which then charge the batteries. Being marketed for disasters and military.
That actually sounds like a viable regulatory hack. Technically an "EV" with "V2G capability", but actually it's a truck full of batteries with solar panels hanging off it.
Eh, it's not unique, it's just that the American ones seem to be so much more empowered, excessive, and capable of generating news and social media headlines.
The UK variant seems to have more traditional failure modes of "excessive charges for maintenance of communal areas": https://parliamentnews.co.uk/tales-of-intimidation-excessive... , but people are still capable of having the occasional fistfight or protracted legal dispute about the wrong kind of hedge in a more informal, adhoc way.
Following the great american "mobile home" tradition. Slap a couple wheels under any object and it is magically removed from countless regulatory rules.
Generally correct. Here in Washington I could get Signature Solar to ship me 31 excellent Canadian Solar bifacial panels on a pallet for $9200 plus tax and shipping (so add another grand or so). This would be 21kW of solar (plus a bit if bifacial gain kicks in), which is a ton - you could even do some winter work with that, if angled correctly.
This setup would cost north of $50k (possibly north of $75k, depending) if installed by contractors. Labor costs are extremely high here, since COL is extremely high.
Rooftop solar generally requires professional installation. Balcony solar, as discussed in the article, does not require professional installation and simply plugs directly into an outlet.
Depends on where you are. I can DIY the physical mounting parts of a rooftop install where I live (San Francisco), but a licensed electrician needs to do (or at least supervise) the wiring.
I do wonder if having an electrician come by after the fact to inspect it counts as "supervising", though.
Here in NM, you can take a "homeowner's solar exam", and if you pass (75%) you can do the full install, including connecting to the grid, yourself.
The exam is much harder than one might expect, but if you're reasonably competent with residential wiring, far from impossible. It covers a bunch of stuff that is irrelevant for 90% of all residental solar installs, naturally.
That pricing is insane. I had 11.3 kWp of panels + 48 kWh of batteries installed in the Bay Area a few months ago, for $40k (shoutouts to Potrero Energy).
I designed / built / installed an 11kw system with 55kwh of batteries in 2024. It was a fun hobby for a year, I loved it. Grid buyback is only $0.03-$0.04/kwh (while cost is $0.37-$0.42/kwh) so, not really worth it. We live among tall trees, but still managed to generate 75% of our yearly solar needs last year.
Permitting was new for me and it was tough to navigate alone, but definitely possible.
Yes, but... I just did a solar install, the utility is likely to confirm you have a building permit for the array, and the utility came by to verify the shutoff works.
If you don't have utility approval to connect, you won't get net metering benefits, although you could offset active use (and if you had battery storage, I guess you could make it work). At least my meter doesn't run backwards, it has a count for energy in and a count for energy out. If we didn't have utility approval and had significant energy out, I'm guessing there would be questions. We have a fairly generous tarrif, and our system doesn't make sense without utility approval --- we generate on one meter and use on another meter and rely on meter aggrigation for the generation and use to offset, and they will offset 1 for 1, once the account gets fully set up.
You might want to check on that net metering. A lot of utilities are moving toward net metering for a specified time (10-12 years or whatever) then moving to net billing. So once you hit the time limit they buy it from you like you're a producer at .03/kwh or whatever their purchase/production cost is.
Well, we already installed the system, so it's too late to change :P
Our utility is still offering 1 for 1 net metering for new installs (accumulated credit expires at the end of March every year) and have not proposed a new rate schedule. They say that existing connected systems will be able to remain on the current schedule indefinitely. That's the best I can do for the future at this point.
If it does change for us in a negative way, I'll have to bite the bullet and buy an electric car and charge when the sun is up. :P Hopefully negative changes happen later rather than sooner.
It depends on where you live. Some places will let you do everything yourself (though you may need to get permits), other places will let you mount the panels but not let you do the electrical, others will let you do the electrical but require an electrician to sign off on it, etc.
Yet another data point: ten years ago it was £5,500 for a 3.9kW system. The largest possible on the "simple" permitting scheme. I did however have to spend another £1000 a few years later on retrofitting bird-proofing. You don't want to build a pigeon farm by mistake.
At that date I got into the feed-in-tariff scheme, and it has long since paid for itself just in cheques mailed to me by the utility.
With the plugin solar I can imagine people in single family residential installing them on both sides of fences and gates to get an around the day benefit.
Also, with the price of solar panels decreasing below most (wood?) building materials with way higher durability, no paint required, why wouldn't it replace most sun facing siding applications aside from being "ugly".
The plug in solar systems are small and usually mounted in ways that don’t capture as much energy as the same panels mounted on a roof. These systems aren’t going to get popular enough to make a big difference in anything.
I think it’s nice that they’re available for people to do some small scale offsets, but I think they’re more of a gateway to better solar installations. They also send people down the path of investigating battery storage add-ons, which might actually be a better long term solution for everyone.
If we can get to a point where we can buy plug-in batteries that are subsidized by requiring coordination with the grid, the power companies could get distributed, controlled battery storage to work with their demand curves. This can already happen with the bigger permanent install batteries.
I really don't understand why most people here act like this is some weird unproven and unsafe technology. This is literally a solved problem. They are everywhere in Germany and it's no issue.
The inverters follow the grid AC and shut off their output if they are disconnected or unplugged, so the plug is never "hot". The power they input into your home wiring/the power grid is limited to 800 Watts as to not overload any installation. And the power meters know not to run backwards if you happen to feed power into the grid. Most can even meter how much power you fed in total (you're not going to get paid for it, though)
If you want, you can add battery storage that follows the same rules but lets you save excess power during the day to feed into your home at night or during demand spikes (washing machine, ...).
The setups are dirt cheap (often 200 - 300 EUR for an inverter and 800 - 1000 W(peak) of solar panels) and pay for themselves in about 1-3 years in saved electricity costs.
EEE here. I've not looked at these in detail myself as they are illegal in my country. Off the top of my head, the big problem I see is that, since you are injecting power BEHIND the circuit breaker an end-user can overload a circuit.
i.e You have a circuit with max current 16A; clever end-user plugs in 3 x 800W panels into different sockets BUT they are unfortunately on the same circuit; now 26A can be potentially drawn through a single cable IN THE WALL without tripping the breaker. This is a BIG fire hazard.
And you can't wave this away with instructions. It has to be 100% impossible for an end-user to do this.
That's why in Germany you are limited to at most 800 W for you house with plug-in solar.
Of course your argument still stands, but we're talking about at most 3.5 A extra current, not 10 A. Home installations seem to be adequately sized to be able to handle that load. At least I'm not aware of any reported incidents, and people have been putting them up for quite a few years already. And typically, German regulations err on the side of caution.
But sure, with 110 V, you will have more problems with the extra current for the same power, so in the American grid there could be further precautions necessary.
You cannot rely on that limit though. People WILL plug in more than that. The whole system has to be kept inherently safe. All other concerns are solvable, but I don't see how you solve this, bar having a special balcony-solar-socket installed where an electrician has verified that it will be safe in all scenarios.
Americans are, for the most part, fucking morons. We invented the infamous warning labels like DO NOT EAT THE TONER CARTRIDGE or DO NOT HOLD THE CHAINSAW BY THE BLADE or REMOVE CHILD BEFORE FOLDING STROLLER or PEANUTS: CONTAINS NUTS
We're also very litigious, as it isn't hard to convince a jury to award damages to a fellow moron.
Italy has the "Do not store your cat under the seat" warning. They do NOT put it on Italian-market scooters and they definitely DO put them on US-market scooters.
Everybody in the world is a moron. Americans just recognize some places where we are morons and try to prevent stupid people (which includes me and you!) from doing some stupid things.
Not everything, Americans do get by with doing other moronic things that other countries do things to prevent. However other countries also do their own moronic things that Americans are much less likely to.
I sincerely get your concern. Clearly explain on the box what NOT to do and be explicit about the risk. Use an icon of a house on fire. Done. Life is risk, and regulating and banning things based on the lowest common denominator of human judgement is a fool's errand. Should we ban vehicles as well since about 40k people die from vehicle related fatalities annually?
Final edit: "61% of respondents support having one device per household circuit while 19% considered that
only a single plug-in solar device should be permitted per premises citing alignment with
44
Engineering Recommendations G98 Issue 2 Amendment 1, impact on the network, old wiring in
properties and the ability of consumers to correctly identify separate electrical circuits.
Government response: Having considered consultation responses and stakeholder feedback,
the government's approach is to limit the deployment to one per power circuit, subject to
corresponding changes to the G98. Some respondents suggested limiting the total capacity per
dwelling to 800VA, but we think the evidence for doing this is weak considering most UK
dwellings have a minimum of two power circuits"
-- i.e. they thought about it and the concerns got outvoted.
It's probably fine. There's a lot worse lurking in outdated UK installations. Then we get on to ring circuits, which the rest of the world disagrees with and also seem to be fine.
Wait, people in the UK actually follow those instructions?
In the US, even with a warning, you'd get regular home fires as people hooked one of these panels into every available outlet just because they can. I wish I were joking.
Wouldn't all three being plugged in be likely to trip the breaker, because it's just AC and the breaker can't really tell whether energy is flowing "forwards" or "backwards"?
Seems like the worst case scenario is when you mix solar panels with load on the same circuit.
800W at 110v is about 7 amps. Suppose you have a 7 amp solar inverter plugged in as the first thing on that circuit. Further down the line, you have 22 amps worth of load. The circuit breaker sees 15 amps, but the wiring between the panel and the load is carrying 22 amps, which would ordinarily trip the breaker but it doesn't because the solar setup is masking it.
I'm not an electrician. Perhaps wiring code has enough safety margin that being 800 watts over on some circuit isn't actually a serious safety concern, but I could understand why this might not be allowed.
The EU is on 230v, so maybe it's a bit more practical over there because you can add twice the solar capacity for the same amount of additional current you'd have in the US, so they aren't eating into the safety margin quite as much. Though it seems they also use thinner wire gauge generally, so maybe the difference is moot.
Yup. Worst case scenario is indeed mixing generation and load on the same circuit. And you have to assume that some number of people will manage to do that and create a fire hazard. To connect it safely, you need to know the circuit layouts and the rating of the cables. This is not something solvable with a safety sticker and safety instructions. A huge amount of effort has gone into making domestic electrical installs as inherently safe as possible and these panels are a back door to that.
Don't get me wrong, I think they're a spectacular idea, especially for renters. But you'd need an electrician to check the circuit and maybe even have a special balcony-solar-plug to prevent people plugging in too many panels in the wrong locations.
Quick edit: Random idea. I guess if the panel could communicate with the RCBO it's connected to and that RCBO can dynamically alter it's trip current could also solve it. But again, that's an electrician call and new thing installed.
I’d also guess bad inverter hardware could cause lots of dirty/noisy AC power effects and damage other equipment on the system. This definitely doesn’t sound like a very safe approach without a lot of conditions being met and exactly like your example there are too many ways it can go wrong.
You might be thinking about it as you might a DC circuit or a battery with electron shuffling one-way down the wire.
But it’s AC, the electrons are shuffling in both directions at 50/60hz
Voltage goes forwards and backwards and odd but current also goes forwards and backwards, for both appliances and generators.
The difference between consumer and producer is only the phase angle between the voltage and current waveform.
Because power is VxA, do that across the wave cycle and the power direction changes for consumers and producers.
At every junction, Kirchhoff’s current law will sum the currents so you get a “net current” waveform on a wire that might have both a kettle and a plug in solar panel.
That summation means the kettle will chomp as much current as the panel can deliver and than take more from the grid. Swap the kettle for a small LED which takes a fraction of the current and the sum gives a NET supply, and on to the next junction.
Maybe a useful mental model is a trampoline? The grid is like a jumping elephant or something (I don't know if they jump, we'll say they do for the sake of the analogy), and you could have people also jumping on the trampoline. If they're a bit late, the elephant launches them in the air, and if they're a bit early the elephant sucks the energy out of their jump, but that energy makes the elephant jump higher. And a fully distributed grid would be one where there is no elephant, just a million people jumping on a trampoline.
I think at this scale that it's cleaner to think of the grid as a flywheel system of enormous (~infinite) mass. Every consumer (home, factory, business, whatever) and every producer (home solar, nuke plant, wind machine, whatever) is connected to this flywheel system, and they're all in parallel (just like circuits in a home are).
Take power out of the flywheel? Sure, why not -- that's exactly what we've done with it at home since we had an AC grid to speak of.
Try to impart higher voltage to put power back into the system? Fine, no worries. Flywheel just accepts and absorbs whatever you put into it as long as it has the right shape.
Try to change the flywheel's AC frequency or waveform, though? Hah, fat chance: Flywheel will trip your breakers or reduce your gear to ash -- whichever comes first. We play by the flywheel's rules, and those rules aren't optional at all. It may be just a big dumb flywheel, but the flywheel's enforcement is absolute.
Anyway, it's a big mythical flywheel. We get charged money to take power out of it, and (with the right arrangements) we get paid money to put power into it.
And by design, grid-tied inverters are quite good at following the flywheel's rules. They match the flywheel's waveform very well [lest they go poof]. They can only put power into that flywheel, and they reject power from that flywheel. The inverter is a one-way thing that, from a high-enough viewpoint, looks kind of like a check valve or a diode does.
---
But it's not an ideal, perfect system. It does not exist in a world of frictionless pulleys and ropes that don't stretch.
That imperfection shows up in the wires and transformers connecting the house to that flywheel system, in that these parts have a non-zero impedance. (For the sake of this discussion, impedance can mean about the same thing as resistance)
And that impedance is useful. It means that we can increase voltage a very tiny bit on our local leg, and thereby succeed at using our puny little solar power system to help cover our own local base load.
Suppose our plug-in solar widget can produce 800 Watts today. The plug-in kit increases the voltage that it drives that plug with until 800 Watts of power output is achieved (which is only a very tiny amount of extra voltage, but it's real anyway). This is its purpose: Where some robots pass butter, this robot puts 800 Watts into a power socket.
Since the wiring between the plug-in solar and the local household baseload stuff has a lower impedance than the path to the mythical flywheel does, our baseload stuff (the fridge, the router, the fan by the window) gets first dibs at that 800 Watts of minutely-enhanced voltage.
If we produce more than we use, the excess local power production gets provided to and soaked up by the flywheel (maybe we get paid for that).
If we use more than we produce, then the deficit is made up for by the flywheel (and we definitely pay for it).
If our generation and consumption is perfectly balanced (which never really happens), then the flywheel plays no real part in the program except to provide a waveform for our solar inverter to synchronize with.
---
Anyway, it's not new tech at all. It's safe in that it won't work at all without a connection to the big flywheel in the sky. And folks have been using grid-tied inverters for quite a long time, but that was done on a dedicated circuit (with a dedicated breaker or fuse or RCBO or whatever they're called wherever you are).
But there's still some new stuff going on: It can be a plug-in system that works without individual planning or permitting; in some places, a person can legally buy and use a kit without obtaining extra permission.
The safety of sharing a circuit is also important, since enhanced potential exists for overheating things. Germany limits their plug-in solar to 800 Watts, or about 3.5A @ 230V, while their circuits are usually 16A.
That means there could be as much as 19.5A of nominal current flow within a circuit before some combination of circuit breaker or inverter limit is reached.
I learned a long time ago to never question a German about their electrical standards, though, so I can only assume that very smart people have worked very long hours to see that this situation is safe-enough.
It’s not even really an issue with DC either, like a lot of people’s battery systems have multiple DC loads and multiple sources (e.g. DC MPPT solar controllers) going to a busbar connected directly to the battery.
Current load pulls the voltage down, sourcing current pushes it up. No bother, as long as your sources cut out if the voltage goes too high, and your loads cut out if it goes too low.
Maybe the issue is in the terminology? In the UK, we don't call it an "outlet", we call it a "plug socket", or just "socket"; it's a socket that takes a plug, no direction is implied.
In terms of electricity and physics, this is unremarkable, the bit that probably scares people is the fact that you have a plug connected to something that's _outputting_ AC, particularly for those of us with 240V supplies.
If it were any old AC source on the other end they'd be correct, but current technology allows the output to be cut in milliseconds, faster than the period of a single AC wave, once the plug is removed.
Tangentially; if you have solar (mine's roof-mounted) don't assume that flipping the breaker means there's no power; I live in a 1930s UK home with all sorts of interesting wiring and flipped the breaker to change a plug socket, only to be shocked; literally and figuratively when it was hot.
No, I think it's that we've been repeatedly told of the dangers of plugging a generator into a socket of the house and the problems that will occur if the power comes back on if it's still running.
When we had our solar installed, we had to make sure we had a newer power meter that could handle power both ways, so it probably is a problem for some situations, but the power flow for a single solar panel into a plug isn't enough to trip this, or maybe newer power meters are better?
We definitely think of it as somewhere a power comes out of, but I don't think it's the name, just that it's only ever been that way.
Clearly some people think of it differently if they're plugging generators into wall sockets to power the whole house, dumb as that may be.
There seems to be several levels of compatibility, at least here in the UK, based on age.
My home is 1930s, it's fuse, in the black Bakelite housing typical of the era was insufficient and we were missing a incoming breaker to/from grid, those were updated. Our meter is much more recent, though still dated; allegedly it would have worked but it wasn't a smart meter, which we wanted so we had that updated.
I've also heard through my many hours of watching Solar videos on YT before our install that some breakers, RCDs(?), RCBOs(?), whichever it is, aren't always suitable for bidirectional current flow, so that's a possible issue too.
All of that is aside the "suicide cord" danger of the old generator method, but that's gone now with modern tech, the output is cut before you can get your hands on the contacts on the end of a plug.
It's just been legalised here in the UK, and I think it will help people with their bills, but the key is to keep installation costs down; if it's DIY you can look at a decent ROI time, but with the cost of trades-people these days, if you have to call out a sparky to inspect before you plug it in, you've added potentially years to your payback period.
At ~800W, I think on the whole we'll be fine; the equipment in our homes has got much more efficient over the years, and our homes were mostly built for times where we were using higher powered devices. If you can draw over a kW to power an electric heater or kettle, I don't see why feeding a mere 800W back in would be a huge risk.
Disclaimer: I'm not an Electrician, but I do have a degree in Electronic Engineering.
You can backload via generator plugged in. Nothing physically stopping it. You just would need to shut off the primary breaker so you don't load the line outside of your house.
The solar is the same way, but with an auto cutoff.
Essentially this is simply what solar panels have done for ages, feed back electricity to the grid, sure it's not through a power outlet but essentially it connects to the grid in a similar way.
What's new is cheap and ubiquitous micro-inverters. Before it wasn't worth putting a $800 inverter on a small 2-panel 600 or 800 installation. Now with micro inverters being so cheap, this tech becomes viable. And with loads so limited (less than a microwave) the regulation is equally light to allow this convenient plug-in solution.
What’s the issue? Electrons flow both ways… Just have to synchronise the AC signals of the inverter to the grid, have good limits on frequency and voltage fluctuation, and monitor for faults properly.
Electrically, this is no different to a regular rooftop solar system. All inverters connect to your household wires like any other device, except that it’s normally on its own circuit and breaker.
This is also how generators work, so it's not new at all, though with a generator you need to disconnect from grid power so you don't electrocute lineworkers. The solar backfeed devices don't work when the power goes out to avoid this (called anti-islanding).
Is it not almost similar to IPS? the device is charging through the power outlet, whenever the power is out, it's inverting and feeding power to the home. This exists for over 20+ years iirc? It works, and haven't heard of any incidents.
For panels and inverters, there's really too many to count, but mostly names that one is not typically familiar with. For integrated solutions, familiar names might for example be Anker Solix or Tepto, which offer battery storage with integrated AC inverters. I'm running an Anker Solix Solarbank 2 E1600, which is not really the latest model but rather cheap and runs nicely.
If you want to get an overview of the ecosystem, googling "Balkonkraftwerk" gives you the most relevant results.
> The system tripped his apartment’s circuit breaker and shut off his computer several times, but a different inverter solved the problem.
I think this will be your biggest practical issue in newer US construction. Arc fault circuit interrupters are now code for any wiring in living spaces. They can be quite sensitive to weird switching loads (and sources). I was forced to swap an AFCI for a normal breaker in my last home. The power supply in my workstation triggered the detection heuristic in the AFCI about once a day. I could cause an outage on demand by running certain workloads.
So your home has multiple circuits. Each outlet in the home is on one of these circuits. If you want to power your fridge, I assume the panel needs to be plugged into the same circuit as the fridge. Is this correct that “you are powering a circuit, not your house”?
No this is not how circuits work in your house. While they are each protected by a separate breaker they are all sharing the same power from the panel bus.
The breakers do not prevent power flowing from an outlet back into the panel bus. They are thermal magnetic trip devices (99% of the time). The thermal is just a strip that when you get too much current for too long gets hot, expands, and trips the switch.
The magnetic part is a coil and too much current too quickly pulls it like a lever.
Nothing here will prevent “backflow” of electricity. It can’t because AC is always going both directions. It is reversing direction 50-60 times a second
The only thing you will hit is whether the power is on the same phase as your fridge. If not it’s going back to the grid.
No, I think the idea is it backfeeds into everything connected by the same wire -- unless the grid shuts down entirely and there's no 60-cycle signal to synchronize to, in which case it shuts down for safety.
The biggest problem with plugging a generator into an outlet is you need a double ended cord. If you use everything correctly they work fine, but there are too many ways things can go wrong. The most obvious one is you plug everything in, start the generator, and the trip over the cord on you way back inside, thus sending the live male end flying toward you. Once in a while a kid will see these dual male plugs and plug them in - lots of ways things can go wrong here.
There is also the problem of backfeeding, but this is more theoretical - even if you know to limit your power use, your neighbors won't and so your generator will trip its own breaker. Linemen are taught to either treat power lines like they are live, or to short them to ground - it can happen they don't do this and you kill a linemen, but still not as big a worry as it is made out.
They make generator "inlets" that sidestep all these problems when used correctly. Most common I've seen is a block so you can't have the inlet and the main breaker both on at once.
> There is also the problem of backfeeding, but this is more theoretical
it is not theoretical from the POV of power company employees working on their lines. the power goes out, they go to fix the equipment or wiring, and if the inverters connected to the grid have not shutdown, there could be 10s of kW to even MWs being backfed into the system they are working on.
that's why in the US at least, grid-tied inverters are required to have protection against this. if they do not see power from the grid, they shutdown (and rather quickly).
Again, all linemen are taught to short the wires or they are alive. All grids have regular places where two different lines meet and there is a switch at those points where in the worst case is they can cut the down line close a switch that normally is open and they can back feed a line from a different one and get power to people who are on each side of the break and then they can come back later to fix the break. These switches are miles apart, which means that you cannot be sure while you're working on the line someone else didn't go to that switch and change it.
Also, people have been back peeking the grid from their home generators for decades by now. Solar and inverters are a different variation of that attack, but it is nothing new. Any utility will have procedures because they can't guarantee that's not happening and we learned years ago.
I'm not saying it never happens, only that correct procedure already makes it not an issue
> if they do not see power from the grid, they shutdown
I realize this is a complete noob question but I'm still curious: with enough "backfeeders" could it not in theory be possible that the backeeders see each other's output and keep operating?
Say, a few houses at the end of the line, each with very little electricity consumption (no-one's at home), but with panels and inverters going full tilt, something like that?
Yes, this is a concern with some older inverter designs. They use phase-locked loops which are meant to lock to the grid frequency but if you and your neighbours on the feeder are generating and consuming a roughly equal amount of energy and the feeder loses its connection to the wider grid, the loops can lock to each other and form a stable island. How long this would last in practice is not really known, it would probably be rare for it to happen at all and even rarer to stay stable for more than a few minutes but it has been demonstrated so it could have become an issue. Newer inverter have specific anti-islanding protection to detect situations like this and disconnect if it happens.
(the specific case of very little consumption but panels and inverters going full tilt doesn't work as this would lead to the frequency rapidly increasing, exceeding inverter set points and the local grid collapsing with all the inverter tripping off. The danger scenario is closely matched load and generation, like a real grid)
Thanks, anti-islanding protection must be a fascinating topic. You could look for voltage, frequency, phase anomalies but you also have to balance between being safe and having too many false positives. I'm not sure I'd want to be a line worker knowing there may be many inverters, from various manufacturers and with varying levels of quality, in every direction.
Perhaps a more robust solution would be for the power company to install remote-switchable circuit breakers at various places of the grid. Use some sort of wireless IoT protocol to listen for "on/off" signals and to report back "I'm now on / I'm now off!". Then the power company can disconnect parts of the network by themselves, without trusting that every inverter, generator and battery will do the right thing.
Apparently the anti-islanding features in the inverters prevent this kind of situation. They need several minutes of clean power to start back up, and do other checks.
Hang on. You didn't address the reason they gave in the half sentence your quote skipped. How are those backfeeders going to keep going when there's way way more load than they can possibly supply?
It's not so much being unplugged as it is sensing whether the mains power is down. If it is, they stop backfeeding immediately, just like hardwired solar inverters do.
If this weren't done, there would be risk of electricution to anyone working on wiring in the house or on the utility distribution network.
Yes, the "balcony" style setups, sync to the power outlet of the house, which could be the grid, or it could augment a generator when the grid is down.
Furthermore, the danger of backfeeding is if you do it in a power outage and you start to power your neighbors' houses. It'll overload your generator and create a hazardous situation for anyone working on the wires. (This is why you're supposed to install either a generator switch or interlock. I have one that only allows me to energize when my main breaker is turned off.)
But how do they do it technically? Some countries require anti-islanding devices for grid connected solar, these are around $1000. That alone is much more expensive than the $300 plug in panels.
The inverter can sniff the grid power at frequent intervals to determine its voltage and phase.
It outputs at the same phase and frequency as the grid, and with a slightly higher voltage (think of a ball rolling down a slope from a higher voltage to lower voltage).
If the grid is down then it stops the inverter for a minimum safety period (some minutes iirc)
Generators are synchronous machines which means they can produce a useful reference frequency without any external source as long as they are spinning at a reasonably correct RPM. This RPM is easy to enforce with mechanical means. This independent operation is also what makes them so dangerous. There is no control signal from the grid back to the generator.
It can be quite safe to plug a generator into an outlet if you take precautions to properly island the system. I had an interlock on my breaker panel that would let me turn on a 50A backfeed breaker if my main breaker was switched off.
In addition to the electronics that others mentioned, they also have limited amperage. That way even if you are pulling from your mains power and the solar at the same time, your circuit hardware shouldn't melt or catch fire.
The back feeding problem is actually identical for plug-in and regular inverters. When the grid goes down, they keep generating power, creating a disconnected 'island'. All inverters are designed to be incredibly unstable in this mode, quickly desynchronizing from each other.
tl;dr Plug-in solar inverters must power off within a second if they stop detecting the grid's sine wave.
Generators have no such protection and will happily backfeed through the transformer outside your house to energize power lines. Line workers are careful, but there have been deaths. After hurricanes seems the most common based on a quick search.
So it's not a stupid question, indeed you should never plug a generator into an outlet. The double-ended "suicide cord" which allows you to do that has that name for a reason. (It can be fine to plug a generator into an inlet circuit, if the electrical panel has a proper interlock that physically forces disconnect from the utility before connecting the generator inlet.)
Yep, if you're gonna redneck the generator after a hurricane, you'd wanna disconnect your house from the grid. One trick in more rural areas is to have your power meter hooked up to one panel, and then your house panel be a "sub panel" to this main panel. Now you can shutdown your main panel and still redneck your house.
The better way (and legal way) to do this is to have a generator plug plug installed, this way when you switch over to generator your property is disconnected from the grid.
I hope the next step for this is plug-in battery storage. All the on-grid battery hybrid inverters I can find in the USA are either single leg 120V or 12kW for $5k. I just want like 3kW dual-leg with support for a dozen kWh of batteries
I've seen setups where they put a 48v battery between the solar panels and plug-in micro inverter. No idea how this impacts efficiency or if there's any safety concerns though.
Yeah it seems like the inverter manufacturers don't see demand for that. I was thinking maybe the Victron Multiplus-II 2x120 could be paired for 240V output but I was wrong, that's only on grid power, it won't make 240V from battery.
Obviously the inverters and pairing technology exist, but I don't know where to buy one retail.
Victron devices on sale in Europe/UK all do 240V output. I've seen someone do a boat build in the USA with Victron hardware that included 240V circuits (because the builder was a UK/US person, and they wanted both 120 and 240 "normal" circuits).
Yeah you can use a Victron 230V inverter along with an Autotransformer to get split phase 240V. Also, I was sort-of mistaken in my earlier comment but can no longer edit it. The MultiPlus II 2x120 cannot make split phase 240V on battery, but I see that the regular MultiPlus II can be paired to do exactly that. About $2K for a setup capable of 240V 20A. Not inexpensive, but it is Victron, which is amongst the best.
> concerns that the energy being pumped into wall sockets could cause wiring in old homes to catch fire, but he says “that’s never happened in Europe,” despite its widespread adoption.
well old NA circuits are notoriously shittier and lower-amp-rated than in europe lol
i don't think it's a good argument against balcony solar but neither is that a good rebuttal
NA is typically higher amp rated than europe. Europe has a lot of 10 amp circuits, 15 is the smallest you will see in NA (you can have smaller in special circumstances but I've never seen it). You might be confused because the US often uses 120 volt circuits which means 15 amps is less watts then 10 amps 240 like you see Europe.
Don't call the US system "shittier". It is different, but that doesn't mean better or worse. Anytime the US needs more a little more power we put in 20 amp circuits for the same wattage. Anytime we need a lot more power we put in 240 volt circuits. Different, but it works just fine.
How do these work when plugged in to only one of the split phases on a US-style 120 system? Because I'm a nerd, I know which legs of the phase go to which outlet in my house, but I don't expect everyone to pay attention to that. I assume something has to take that into account somewhere.
There is no problem and so nothing needs to account for it. A split phase is just a transformer with three windings, and one is connected to the other. We call one side (high voltage) the primary, and the other two secondary, but the transformer doesn't care at all, it can send power either way (there are limits but we are well under the maximum rating of the transformer so we can ignore them). If you only draw 240 volts then the two connected windings act as a single secondary, if you only draw 120 then one of the two secondaries provides power. Any other combination - the transformer doesn't care.
U.S. homes typically get power through two hot wires. The hot wires are connected to a utility company's transformer and are 180 degree out of phase. Each supplies 120 volts.
The power from the plug-in outlet is consumed by any devices connected on the same circuit first. Any extra flow through the electric panel’s bar connecting the circuits on the same 120V phase, where the devices on them use the extra next. Any excessive power flows back out of the meter on the 120V phase line on your service connection to the transformer at the street block. The transformer might feed it to your neighbors. In any case the transformer feed electricity to the other 120V phase line back into your service connection, the meter, the panel, the other split phase bar, the circuits on it, and the outlets on them. The devices on the other split phase circuits technically are not using the plug-in power directly.
Most modern meters measure electricity going in and out on both split phase lines as a whole, as a net amount, so the electricity consumed in the other split phase circuits is offset by the plug-in power. However some old meters add the outgoing electricity up as consumption so you are paying for the electricity fed into the grid. Call your utility company to make sure.
Also, unless you have a net metering agreement with your utility company, you won’t get paid for any excessive electricity fed back into the grid.
I doubt it matters. The power company also theoretically has to deal with houses where they coincidentally draw more from one side of the split than the other. But I suspect it all averages out, and the contribution of a couple plug-in panels in a bunch of houses won't change anything.
It backfeeds onto the grid and becomes the utility companies problem to deal with. This is similar to them dealing with a house that is an unbalanced consumer between the legs.
To my understanding, it is basically a non-issue at residential voltages. To be a problem it would require all the houses on a transformer (there are typically just a few for each transformer) to be unbalanced significantly in the same direction. That would be the end of it, too, because the 240V split only happens at the transformer.
I did the math for my rates and missed opportunity costs and the payback is almost 8 years for 900w system at $1500 which is cheap. Do your own math before you purchase
My concern is what happens to grid stability as we replace synchronous generators, with their enormous rotational inertia, with thousands of grid-following inverters. They can all phase-lock to 60 Hz, but without enough inertia, what keeps that frequency stable during sudden changes in load or generation?
Synthetic inertia. Essentially, loads that you can quickly either shed or bring on in response to fluctuations. There can be a market for that too and that's what many grids are slowly discovering.
There are still a lot of synchronous motors out there directly wired that provide real inertia. Though these two are moving to VFDs (which are cheap and variable speed). Still I expect battery backup systems will come online more than fast enough to replaces the losses.
I don’t see many (any?) plants using them, is the technology there yet? Genuinely curious.
And on an unrelated note, it seems that hybrid power plants are becoming a talking point now and they seem to make a lot of sense. Like covering dams with solar panels saves on water, make PVs cooler/work more efficiently and you don’t need to worry about permits/building more grid connections because you can simply slow down hydro during daytime (and get along with grid following inverters just fine).
The technology to act as inertia isn't actually hard, is it? You deliberately offset your voltage by a fraction of a millisecond and you have to handle some percent extra current.
Perhaps also useful would be plug in batteries, especially if one has variable rates. Charge when cheap, discharge when expensive.
One constraint on these I've read is that if you have sources and sinks on the same circuit, you might overload the line without tripping the breaker at the box. If I'm understanding this correctly this has caused them to limit the power of plug-in solar to a fraction of what a single circuit could potentially carry.
Problem with this idea is batteries on grid scale are always cheaper per MWh, so grid scale battery operators will eat away any arbitrage you could earn with more expensive consumer gear.
I'm not trying to make money here though. I'm trying to recoup some of my costs for a home backup for when the grid fails. My house automatically switches to a backup generator when the power goes out, but it is from the 1970s and wearing out, a battery system that can recoup some of the costs by arbitrage is useful even if it loses money.
While the power doesn't go out often, it is a big deal when it happens and so a backup is useful. I'm still fixing the damage from the last one - the sump pumps not running for an hour in a rain storm is expensive. Fortunately it wasn't a long outage, much longer and the fridge/freezer would be a problem. In cold weather the furnace is important to keep running. There are other essential things as well that my house cannot survive without. Beyond that I want my computers to keep running if possible.
There's not sufficient grid scale capacity yet, there are lots of consumers arbitraging in the UK.
My electricity supplier sends me a message nearly every week saying if I use less electricity during peak demand times then I get free power at weekends. https://octopus.energy/saving-sessions/
I've been doing this as well! It's always 6pm-7pm for me which is when my Cosy tariff has the peak rate anyway, which I try to not use. So for no behaviour change I normally get 1-2hrs of free electricity on a Sunday morning! I got 15kWh for free this week by having the immersion, heat pump, washing machine and tumble dryer running. Not bad for 0 effort on my part.
Yes, it's designed so that total current and potential heat problems are still within safety margins of circuits built according to code. In most of Europe, one regular (or upper end of regular, depending on country) residential circuit can supply 3.6 kW (230 V * 16 A = 3680 W), so 800 W are "just" a 20% overload.
I have two sets of these..very cheap if you order it on Amazon yourself. And very easy to connect.
The big panels are a bit of a hassle because of the size, not the weight.
There are advantages to distributed infrastructure as well! You mentioned one of the biggest disadvantages.
I am thinking along the line of:
- You can just do it / upgrade it etc
- Robust against central failures for various reasons
- Resistant to those in charge of centralized infrastructure abusing their monopoly
Utility solar is also distributed if there is enough of it installed to matter for discussion. A single installation is such a tiny share of the electric load that we can ignore if for all reasons you care about distributed. (or care about solar for that matter - it is a drop in the ocean for the environment)
Utility-scale solar might be cheaper but doesn't make my house resilient to grid failures. It also only benefits me when the grid is upgraded enough that ... well, it benefits me.
Plug in solar doesn't make your house resilient to grid failures either. You would need an inverter that can generate an AC output without having an existing one to follow; a disconnect to isolate you from the grid during an outage, batteries to smooth the output, an electrician to install it, and an inspection to certify that it was all done correctly.
If you are going through all of that, there is not much benefit to plug-in solar instead of traditional.
Most of the balcony solar packages already include what you need. They include a battery and on that battery is a receptacle that will supply power if there is no mains. The dogtail that you insert into your house outlet only supplies power if there is mains, but the receptacle on the battery supplies power regardless.
So when the power goes out you unplug your fridge from the wall and plug it into the battery. In essence it operates like the standard camping battery/"solar generator", a la Jackery et al.
To gp’s point, if you’re going through it all just implement it at your panel/subpanel. Mine does auto switch over to power the entire panel and I only know about it from an app notification. Then I can decide if and where I want to power down usage in the house to conserve battery.
Having to plug in individual appliances seems to defeat the entire purpose. What happens if you’re away on holiday? Come home to a fridge full of trash? If power is back, do you even know how long the outage lasted? What about other devices that generally should have nonstop power or are typically hardwired? Sump pumps, HVAC equipment, water heaters, etc.
You can go as far down the rabbit hole as you want. Most people don't have anything critical that needs to have power 100% of the time, a few hours without power won't hurt your fridge. The odds that the power goes out for long while you are on vacation is low enough that you can ignore it - besides most people tend to have less in their fridge when they go on vacation.
Where on the risk spectrum do you fall? I have a battery backup sump pump because I learned the hard way what happens when the power goes out and the generator doesn't start. If I fixed my generator though I'd have an automatic system that would run my sump pump, furnace, fridge, well, water heater, lights, computers, range, - and lots of other useful things as well so long as I'm careful about I run at the same time (anyone know how to fix a 1970s generator?)
This is the truth. Aside from solar there are plenty of folks with backup generators that automatically come on whenever grid power fails. When maintenance crews came through my neighborhood to upgrade the old pole fixtures, they grounded out each block to keep any backfeed off what they were working on.
No, it's more than that, it's not just a safety feature that you could disable: the plug-in panels need an existing waveform to synchronize to, if the grid is dead they can't produce an AC voltage signal on their own.
We know how to make inverters that can produce an AC voltage on their own. It is not particularly difficult or expensive. The reason why we do not put those inverters in plug-in solar units is entirely because we don't want them to have that ability.
Those are a different design inverter than cannot plug into a wall. It isn't hard to design either type, but they need different designs in some critical areas. (you can design one that will do both as well, but it would be more complex)
NW florida just had a hurricane. As I type this comment there are hundreds of thousands of people in the sunshine state that have no (grid scale) solar power. That from a heavily solar provider. All of my friends report that (largely) trees are down but houses and roofs are okay. Distributed solar would have a lot more people with working refrigerators and unspoiled food.
You don't even need distributed solar. A simple UPS is enough, either plugged in in front of the refrigerator or wired to the entire home via a transfer switch... and hell it's not that expensive. Battery stations capable of feeding a refrigerator for a day are less than a grand, if you don't want batteries a gas-powered generator is even cheaper.
Just how many natural disasters do Americans go through before realizing that?!
Hurricanes a much bigger natural disasters then you think. Several weeks without power isn't unheard of. The battery that runs your fridge for a day will be dead before the weather clears up enough that it is safe for workers to attempt to restore power.
These disasters are rare though for any one person - a few happen every year, but it will be years between you personally seeing a disaster. That is why generators sell out when there is a storm: even if you have a generator odds are it is rusted and won't work. It is a waste of money to buy a generator before you need it.
18.8% Nuclear and 8.4% solar (more than double the national average!)
OUC on the other hand has less than 3% Nuclear (generated / purchased from FPLs plant on Hutchinson Islans!) and <6% solar, with a massive 24% still being generated by coal! (FPL demolished their last coal plant ~8 years ago in Indiantown, I watched it live!)
So while FPL is technically for profit and OUC is not... FPL is cheaper and greener than OUC.
I say this as a long time Florida resident who remembers when FPL truly sucked in many ways. They’ve, demonstrably, put in effort to make electricity greener and cheaper here in FL. (Even with all of their efforts against home solar).
It is easier to find a million people with a few hundred euros and a sunny balcony than finding one dude with a few hundred million euros and land on which building a solar farm is permitted.
With a much higher capital and regulatory hurdle. By individuals self motivated to reduce their own costs with their own small capital investment you get a power source that’s crowd sourced. It doesn’t have to be as efficient to be more effective.
Isn’t it backwards? If everyone had a little bit of home generated power, then the actual energy part of the bill becomes smaller, and the cost of transmission becomes an even greater fraction of the total cost.
And since transmission cost is typically bundled with the energy cost, it means the final retail energy price has to go up to cover the transmission cost.
With less energy drawn over the wire, the transmission cost goes down since less transmission infrastructure being used. The overall transmission cost should go down as well since there's less need to expand the transmission infrastructure.
Where I live we have Time of Day electricity pricing where the prices jump 2-3x during high demand. Panels conveniently produce the most power around this time, so this can save people money.
Utility companies are not incentivized to lower prices because it means less money for them. Do you remember when power companies told people to conserve power and then people successfully did this? And then they raised rates because they weren't making enough money? This happens in California ALL THE TIME. I've lived here 30 years in Silicon Valley and it's the biggest scam that no one talks about. It happens with electricity and water. With water its even more egregious because they told us to conserve water because of the "drought" but once the drought was over, they raised rates because people weren't using enough water. My connection fee to water is over $100/month without spending a drop of water. That's why I stopped conserving water and water my lawn every single day because it turns out that my water costs are only about 1/3 of the actual water bill costs so fuck it!
It's the same playbook over and over again, there's no incentive to lower rates at all because it's an easy way to make money over an entire population of tens of millions of people.
Now PG&E is fighting to charge solar panel owners $100+/month just for the privilege of being connected to the grid. That would make having solar panels even more expensive than not having solar panels which is utter hypocrisy but no one seems to care or point this out. It's a complete and utter scam.
EDIT: I forgot to mention last year the rates were $0.37-0.45 per kWh, until this year when they implemented a base fee of $25/month, so they lowered it to $0.33-0.45/kWh. Rates in Nevada are 1/4 of that.
2015: $0.17-0.33 per kWh
2020: $0.24-0.38 per kWh
so prices have more than doubled in 10 years. Fucking criminals.
I live in Florida, and I'm building a water battery, so I can freeze it at night when electricity rates are cheap, and use it to cool the house during the day.
The day after the system goes live, they'll probably announce flat rates for any time of day, just to f' with me. :(
You wouldn't happen to be sharing this builds information publicly would you? I can fully respect however if you are not.
I am a staunch DIY serial entrepreneur techie that has used my grey goo to build and sell a few companies and my time now is spent similar to yours although using a different application of physics. I too am motivated, just as you are, in my efforts to apply what I know to further reduce my energy costs which will not stop rising for quite some time.
You really made my day with this post and I hope we can find more folks like ourselves from your share because in time 'dogfooding' new ideas at home will lead to new applicable discoveries for all.
> The day after the system goes live, they'll probably announce flat rates for any time of day, just to f' with me. :(
Every system like yours works to flatten the prices, but it looks like a pretty big swing between peak and off peak pricing today, so it'll probably be a while before flat pricing again.
By that logic literally everything should be distributed. That's going to be a big undertaking to re-architect our entire civilian infrastructure against that.
I'm not saying you're necessarily wrong, I just don't see society taking that measure until it's either 1) cheaper, or 2) the threat moves from being just a threat to reality.
> 2) the threat moves from being just a threat to reality.
Completely agree. But I'm already there. Large scale economic disruption has just started. For that to remain peaceful over the next few decades would be a miracle. So we should plan for disruption, for which energy decentralization is a keystone, and the technology to make it practical is here.
California has a 600 MW Virtual Power Plant composed of Tesla Powerwall batteries in 85k homes. Central control of distributed generation removes a lot of inefficiencies. Household excess is available to the whole system.
Has no one been paying attention to how Ukraine/Russia and now Iran has been targeting civilian infrastructure? All of Spain's electricity was down last year from a cyberattack. This is completely a new line of threat that we need to address.
There are significantly better targets than fields of solar panels. There are 132 oil refineries in the country. Taking out even one would have immediate repercussions to energy security which are not easily rectified.
There are probably only a handful of backbone transmission routes which serve tens of millions of people. These are isolated and unprotected and could likely be disabled with a loaded truck plowing into a critical piece of infrastructure.
There are things called distribution yards, they are very distinct on google maps, can't be hidden. They were successfully targeted by US in 1990s Yugoslavia war.
It does not take much to bring down electricity distribution.
Does this seem like a bad idea from a safety perspective?
With fixed solar installs you're likely to find some kind of switch or labeled breaker to disconnect. The system is designed with a central "power in" that's (hopefully) obvious/proximate when you're standing in the breaker room.
These things could be injecting power anywhere, so you need to know they're there (which may be less apparent than roof/field panels) and go around and pull the plug(s). Relevant to electricians, firefighters, etc.
Yes, there are serious safety concerns. Both islanding, which is where a circuit is hot when it shouldn't be, and from a circuit overload.
Your circuit breaker protects your circuits by putting all the load (eg your microwave) on one side, and your supply (mains power) on the other. If too much load is present, the circuit breaker trips.
However, plugin solar puts invisible supply on the load side, which your circuit breaker cannot see. Let's make an absurd example so you can see what the problem is, then scale it back.
Imagine someone buys 5 panels that can each supply 5amps. They plug them into outlets on a 40 amp circuit. They then proceed to run their toaster, microwave, vacuum, and hair dryer. They can draw 65 amps through the wires before the circuit breaker trips. (40 from mains, 25 from the panels)
Let's say they had a good electrician who installed 6AWG wiring on that circuit, which is rated for 50 amps. The circuit breaker used to trip at 40, so no problem. But now up to 65 can go across the wires and suddenly you are exceeding rating for wires.
Now you might say, "most of these are 3.5 watts, and they clearly say don't use more than one". But I say that's a "good intentions solution". We should make it mechanically impossible to do the wrong thing. Maybe these panels could try to communicate over the electrical wires, and if they detect a signal from another panel they should self limit. Maybe we need to rethink circuit panel design. But as it stands people will absolutely buy one of these, decide they love it, and then buy 4 more.
I think this is probably fine, since UK circuits are typically 20A. Apart from fault current (which would have to be line to line, since line to ground would trip the RCD), it's quite hard to end up with more than 20A of stuff plugged into regular sockets unless you're overinvested in portable heaters. All the big stuff - cookers, heat pumps, showers - is on separate breakers from the sockets.
In the original example, RCD/circuit protection is regulated on the _property_ side, e.g UK has EICR for electrical install. Once its done for a property, its good until next inspection (in theory)
This moves the protection to the _appliance_ , which while it needs to meet certification, is much harder to police a consumer electronic device, than a physical unmovable premise.
I think these are great, but there will inevitably be devices that don't implement the spec correctly that still get sold to willful or unwillful consumers that result in danger to everyone.
These rely on seeing a grid frequency to follow when they output power. If you shut off the breaker for the circuit they're on, no grid frequency to follow, and they shut off their output. When unplugged, the plug never has any voltage on it.
Plug-in solar is suboptimal in many ways, but it does sidestep a lot of those hurdles. Not too surprised to see it on the rise.
Another thing that might be worth keeping in mind is that plug-in solar panels are often installed vertically - i.e. balcony solar. In which case the peak of the panel's generation is offset to the edge of the typical "duck curve". If it gets popular enough to affect the grid, it might get the solar-induced demand slump larger, but make the edges even sharper.
Would that make grid scale battery storage with its instant response even more important?
For the price you’re talking about, you could also get a system with 15 kW of panels with a good 20-30 kWh of battery storage too!
It's the regulation cost that's really hurting us.
Just the required paperwork for the permit in my region cost ~2.5k. structural engineer was 800, architecture diagram was 800, certified electrician stamp on the plans was 800.
Add in the extra cost to facilitate RSD (~5k after mlpe devices, and extra wiring) and tack on the cost for utility interconnection agreements.
Then deal with the NEC requiring UL listed items with no/very little cross certification with things like CE which effectively means you can't buy equipment from China, at least not without a US shop taking a huge markup for branding/certs.
---
Overall, it's just a mess. I walked away from the project (completed, all approved) with a huge dose of skepticism for the permitting/certification/approval process.
11.2kw in panels, ~12kwh lfp battery, split phase 240v install - ~28k usd.
Of which ~10k was regulation driven, and doesn't change much by install size.
"Balcony solar" (<800W) with absolutely zero paperwork (edit: I'm wrong, still needs G99) has just arrived to the UK.
Current lowest costs from national retailers that I've found (been looking today as it happens!) is City Plumbing - £336 for 475w, £480 for 1050w (panels with 800w max inverter).
The specific exclusion of batteries too is a sop to the industry. It’s a step forward, but needs to go further.
Currently in the U.K. they have to have U.K. appeal not just standard eu approval. Hopefully this will be fixed by next year and prices will Be more reasonable.
Hopefully too regulators will Change to allow battery Storage as long as it’s not pore than 800W inverter.
Personally, I'd love to see the United States, and the rest of the world, decrease its reliance on oil. We won't get off it in any of our lifetimes, but we should move in that direction. I like diversifying. Any bit helps. Solar in Australia and Arizona. Maybe less so in northern Maine. Wind turbines where there's wind. I personally don't have any aesthetic objection to them. I think they look kind of cool. And certainly better than smokestacks. And so on.
I've been doing some advocacy work related to balcony solar mostly from a conceptual standpoint but am a renter and don't know much about the actual costs and process behind installing roof panels. I'm curious to know whether there are any low-hanging fruit we could organize around to reduce the regulatory burden on the consumer.
No need for permits for rooftop solar and the only dealings I had with the energy company was filling out an online form to register it. Took maybe 2 minutes.
From where did you source the equipment?
400V TN 3P grid with export where I am paid spot. Had to fill in a form online that got approved automatically. The energy company (separate from the grid company) automatically detected my export and started deducing the sales of solar from the bill.
The installer had to confirm the installation to the Enova government entity to release my €3k subsidy though.
I just contacted a well-reviewed solar installer and they took care of everything.
My family got an fixed three phase setup with a 12kWp, 8 kWh battery (BYD) and a Hybrid Inverter (SMA) alongside a Level 2 22 kW EV charger for a grand total of 16.000€.
My plugin solar setup was a DIY with 1kWp of panels + an 800W inverter and did cost a total of 350€, including the mounting hardware.
I did not add a battery because at the time it would have doubled the price. Also, because I have net metering the battery never pays itself off.
(My installer ended up flaking on me, and then I gave up because NEM 3.0 was coming too soon to find a fallback.)
At least you bought them 8 years ago and not 20, you could have had a 1.5kW system for the same price.
Homeowners are getting the short end, but the solar installers are doing well.
Here's a long podcast episode talking about why it's so much more expensive in the US versus Australia, with a solar expert from Australia that had just added a bunch of C&I solar here in the US:
https://www.volts.wtf/p/whats-the-real-story-with-australian
Local permitting, utility fuckery, tariffs, etc. all add up.
The far lower costs in Australia are not due to executive pay, it's due to basic efficiency. Americans are doing things in horrendously wasteful ways, because the system is set to act that way, and changing our system of government is too difficult due to political infighting. One of many examples in the article:
> These things are highly optimized that companies will try to do the scheduling so they’re doing two or three jobs on the same street or in the same suburb on the same day, so they don’t have to drive across town to do the second job. If there’s a delay of a couple of days, it’s because they’re trying to make sure that they’re going to do your neighbors at the same time they’re going to do yours. The thing that costs you money in contracting is what they call truck rolls. I believe in the US there’s something like five or six truck rolls per solar installation. In Australia, it’s as few as one or two.
See also the US healthcare system. Or residential building.
> I'm in Europe
Wait until you hear about American Insulin.
That’s the total cost including all materials and labour from scratch to a fully functioning system.
We (northern part of Germany) installed 7 KW panels with 10 KW battery for €15K in 2024. My neighbor is installing 10 KW panels with 10 KW battery for €18K this week. So it seems the total costs have not dropped any further in the last 2 years.
Matt Ferrell just did a video on this recently https://www.youtube.com/watch?v=R3eEzdpi12I
[0] https://www.sesame.solar/
The UK variant seems to have more traditional failure modes of "excessive charges for maintenance of communal areas": https://parliamentnews.co.uk/tales-of-intimidation-excessive... , but people are still capable of having the occasional fistfight or protracted legal dispute about the wrong kind of hedge in a more informal, adhoc way.
Just lookout for tornadoes.
This setup would cost north of $50k (possibly north of $75k, depending) if installed by contractors. Labor costs are extremely high here, since COL is extremely high.
I do wonder if having an electrician come by after the fact to inspect it counts as "supervising", though.
The exam is much harder than one might expect, but if you're reasonably competent with residential wiring, far from impossible. It covers a bunch of stuff that is irrelevant for 90% of all residental solar installs, naturally.
Free refills on soft drinks are generally still a thing in the U.S.
$30k is mad.
You mean "to have installed".
I installed 6.7kW for $12k, but did all the work myself (with a permit).
Permitting was new for me and it was tough to navigate alone, but definitely possible.
If you don't have utility approval to connect, you won't get net metering benefits, although you could offset active use (and if you had battery storage, I guess you could make it work). At least my meter doesn't run backwards, it has a count for energy in and a count for energy out. If we didn't have utility approval and had significant energy out, I'm guessing there would be questions. We have a fairly generous tarrif, and our system doesn't make sense without utility approval --- we generate on one meter and use on another meter and rely on meter aggrigation for the generation and use to offset, and they will offset 1 for 1, once the account gets fully set up.
Our utility is still offering 1 for 1 net metering for new installs (accumulated credit expires at the end of March every year) and have not proposed a new rate schedule. They say that existing connected systems will be able to remain on the current schedule indefinitely. That's the best I can do for the future at this point.
If it does change for us in a negative way, I'll have to bite the bullet and buy an electric car and charge when the sun is up. :P Hopefully negative changes happen later rather than sooner.
At that date I got into the feed-in-tariff scheme, and it has long since paid for itself just in cheques mailed to me by the utility.
I got 7.6kW fully installed with inverter for $8k CAD a few years ago.
Also, with the price of solar panels decreasing below most (wood?) building materials with way higher durability, no paint required, why wouldn't it replace most sun facing siding applications aside from being "ugly".
The plug in solar systems are small and usually mounted in ways that don’t capture as much energy as the same panels mounted on a roof. These systems aren’t going to get popular enough to make a big difference in anything.
I think it’s nice that they’re available for people to do some small scale offsets, but I think they’re more of a gateway to better solar installations. They also send people down the path of investigating battery storage add-ons, which might actually be a better long term solution for everyone.
If we can get to a point where we can buy plug-in batteries that are subsidized by requiring coordination with the grid, the power companies could get distributed, controlled battery storage to work with their demand curves. This can already happen with the bigger permanent install batteries.
They already are in a few countries.
The inverters follow the grid AC and shut off their output if they are disconnected or unplugged, so the plug is never "hot". The power they input into your home wiring/the power grid is limited to 800 Watts as to not overload any installation. And the power meters know not to run backwards if you happen to feed power into the grid. Most can even meter how much power you fed in total (you're not going to get paid for it, though)
If you want, you can add battery storage that follows the same rules but lets you save excess power during the day to feed into your home at night or during demand spikes (washing machine, ...).
The setups are dirt cheap (often 200 - 300 EUR for an inverter and 800 - 1000 W(peak) of solar panels) and pay for themselves in about 1-3 years in saved electricity costs.
i.e You have a circuit with max current 16A; clever end-user plugs in 3 x 800W panels into different sockets BUT they are unfortunately on the same circuit; now 26A can be potentially drawn through a single cable IN THE WALL without tripping the breaker. This is a BIG fire hazard.
And you can't wave this away with instructions. It has to be 100% impossible for an end-user to do this.
Of course your argument still stands, but we're talking about at most 3.5 A extra current, not 10 A. Home installations seem to be adequately sized to be able to handle that load. At least I'm not aware of any reported incidents, and people have been putting them up for quite a few years already. And typically, German regulations err on the side of caution.
But sure, with 110 V, you will have more problems with the extra current for the same power, so in the American grid there could be further precautions necessary.
We're also very litigious, as it isn't hard to convince a jury to award damages to a fellow moron.
https://members.modernvespa.net/brian_herwick_-_coolass/uplo...
Not everything, Americans do get by with doing other moronic things that other countries do things to prevent. However other countries also do their own moronic things that Americans are much less likely to.
> you can't wave this away with instructions
But apparently you can with legislation about instructions.
Edit: government safety investigation https://assets.publishing.service.gov.uk/media/6a32bfea0bea2...
Final edit: "61% of respondents support having one device per household circuit while 19% considered that only a single plug-in solar device should be permitted per premises citing alignment with 44 Engineering Recommendations G98 Issue 2 Amendment 1, impact on the network, old wiring in properties and the ability of consumers to correctly identify separate electrical circuits.
Government response: Having considered consultation responses and stakeholder feedback, the government's approach is to limit the deployment to one per power circuit, subject to corresponding changes to the G98. Some respondents suggested limiting the total capacity per dwelling to 800VA, but we think the evidence for doing this is weak considering most UK dwellings have a minimum of two power circuits"
-- i.e. they thought about it and the concerns got outvoted.
It's probably fine. There's a lot worse lurking in outdated UK installations. Then we get on to ring circuits, which the rest of the world disagrees with and also seem to be fine.
In the US, even with a warning, you'd get regular home fires as people hooked one of these panels into every available outlet just because they can. I wish I were joking.
Seems like the worst case scenario is when you mix solar panels with load on the same circuit.
800W at 110v is about 7 amps. Suppose you have a 7 amp solar inverter plugged in as the first thing on that circuit. Further down the line, you have 22 amps worth of load. The circuit breaker sees 15 amps, but the wiring between the panel and the load is carrying 22 amps, which would ordinarily trip the breaker but it doesn't because the solar setup is masking it.
I'm not an electrician. Perhaps wiring code has enough safety margin that being 800 watts over on some circuit isn't actually a serious safety concern, but I could understand why this might not be allowed.
The EU is on 230v, so maybe it's a bit more practical over there because you can add twice the solar capacity for the same amount of additional current you'd have in the US, so they aren't eating into the safety margin quite as much. Though it seems they also use thinner wire gauge generally, so maybe the difference is moot.
Don't get me wrong, I think they're a spectacular idea, especially for renters. But you'd need an electrician to check the circuit and maybe even have a special balcony-solar-plug to prevent people plugging in too many panels in the wrong locations.
Quick edit: Random idea. I guess if the panel could communicate with the RCBO it's connected to and that RCBO can dynamically alter it's trip current could also solve it. But again, that's an electrician call and new thing installed.
I passed high school physics with good grades, so … I’m not surprised other people instinctively say this can’t possibly be a good idea.
But it’s AC, the electrons are shuffling in both directions at 50/60hz
Voltage goes forwards and backwards and odd but current also goes forwards and backwards, for both appliances and generators.
The difference between consumer and producer is only the phase angle between the voltage and current waveform.
Because power is VxA, do that across the wave cycle and the power direction changes for consumers and producers.
At every junction, Kirchhoff’s current law will sum the currents so you get a “net current” waveform on a wire that might have both a kettle and a plug in solar panel.
That summation means the kettle will chomp as much current as the panel can deliver and than take more from the grid. Swap the kettle for a small LED which takes a fraction of the current and the sum gives a NET supply, and on to the next junction.
It took me a while to get my head round it too.
Take power out of the flywheel? Sure, why not -- that's exactly what we've done with it at home since we had an AC grid to speak of.
Try to impart higher voltage to put power back into the system? Fine, no worries. Flywheel just accepts and absorbs whatever you put into it as long as it has the right shape.
Try to change the flywheel's AC frequency or waveform, though? Hah, fat chance: Flywheel will trip your breakers or reduce your gear to ash -- whichever comes first. We play by the flywheel's rules, and those rules aren't optional at all. It may be just a big dumb flywheel, but the flywheel's enforcement is absolute.
Anyway, it's a big mythical flywheel. We get charged money to take power out of it, and (with the right arrangements) we get paid money to put power into it.
And by design, grid-tied inverters are quite good at following the flywheel's rules. They match the flywheel's waveform very well [lest they go poof]. They can only put power into that flywheel, and they reject power from that flywheel. The inverter is a one-way thing that, from a high-enough viewpoint, looks kind of like a check valve or a diode does.
---
But it's not an ideal, perfect system. It does not exist in a world of frictionless pulleys and ropes that don't stretch.
That imperfection shows up in the wires and transformers connecting the house to that flywheel system, in that these parts have a non-zero impedance. (For the sake of this discussion, impedance can mean about the same thing as resistance)
And that impedance is useful. It means that we can increase voltage a very tiny bit on our local leg, and thereby succeed at using our puny little solar power system to help cover our own local base load.
Suppose our plug-in solar widget can produce 800 Watts today. The plug-in kit increases the voltage that it drives that plug with until 800 Watts of power output is achieved (which is only a very tiny amount of extra voltage, but it's real anyway). This is its purpose: Where some robots pass butter, this robot puts 800 Watts into a power socket.
Since the wiring between the plug-in solar and the local household baseload stuff has a lower impedance than the path to the mythical flywheel does, our baseload stuff (the fridge, the router, the fan by the window) gets first dibs at that 800 Watts of minutely-enhanced voltage.
If we produce more than we use, the excess local power production gets provided to and soaked up by the flywheel (maybe we get paid for that).
If we use more than we produce, then the deficit is made up for by the flywheel (and we definitely pay for it).
If our generation and consumption is perfectly balanced (which never really happens), then the flywheel plays no real part in the program except to provide a waveform for our solar inverter to synchronize with.
---
Anyway, it's not new tech at all. It's safe in that it won't work at all without a connection to the big flywheel in the sky. And folks have been using grid-tied inverters for quite a long time, but that was done on a dedicated circuit (with a dedicated breaker or fuse or RCBO or whatever they're called wherever you are).
But there's still some new stuff going on: It can be a plug-in system that works without individual planning or permitting; in some places, a person can legally buy and use a kit without obtaining extra permission.
The safety of sharing a circuit is also important, since enhanced potential exists for overheating things. Germany limits their plug-in solar to 800 Watts, or about 3.5A @ 230V, while their circuits are usually 16A.
That means there could be as much as 19.5A of nominal current flow within a circuit before some combination of circuit breaker or inverter limit is reached.
I learned a long time ago to never question a German about their electrical standards, though, so I can only assume that very smart people have worked very long hours to see that this situation is safe-enough.
Current load pulls the voltage down, sourcing current pushes it up. No bother, as long as your sources cut out if the voltage goes too high, and your loads cut out if it goes too low.
In terms of electricity and physics, this is unremarkable, the bit that probably scares people is the fact that you have a plug connected to something that's _outputting_ AC, particularly for those of us with 240V supplies.
If it were any old AC source on the other end they'd be correct, but current technology allows the output to be cut in milliseconds, faster than the period of a single AC wave, once the plug is removed.
Tangentially; if you have solar (mine's roof-mounted) don't assume that flipping the breaker means there's no power; I live in a 1930s UK home with all sorts of interesting wiring and flipped the breaker to change a plug socket, only to be shocked; literally and figuratively when it was hot.
When we had our solar installed, we had to make sure we had a newer power meter that could handle power both ways, so it probably is a problem for some situations, but the power flow for a single solar panel into a plug isn't enough to trip this, or maybe newer power meters are better?
We definitely think of it as somewhere a power comes out of, but I don't think it's the name, just that it's only ever been that way.
Clearly some people think of it differently if they're plugging generators into wall sockets to power the whole house, dumb as that may be.
My home is 1930s, it's fuse, in the black Bakelite housing typical of the era was insufficient and we were missing a incoming breaker to/from grid, those were updated. Our meter is much more recent, though still dated; allegedly it would have worked but it wasn't a smart meter, which we wanted so we had that updated.
I've also heard through my many hours of watching Solar videos on YT before our install that some breakers, RCDs(?), RCBOs(?), whichever it is, aren't always suitable for bidirectional current flow, so that's a possible issue too.
All of that is aside the "suicide cord" danger of the old generator method, but that's gone now with modern tech, the output is cut before you can get your hands on the contacts on the end of a plug.
It's just been legalised here in the UK, and I think it will help people with their bills, but the key is to keep installation costs down; if it's DIY you can look at a decent ROI time, but with the cost of trades-people these days, if you have to call out a sparky to inspect before you plug it in, you've added potentially years to your payback period.
At ~800W, I think on the whole we'll be fine; the equipment in our homes has got much more efficient over the years, and our homes were mostly built for times where we were using higher powered devices. If you can draw over a kW to power an electric heater or kettle, I don't see why feeding a mere 800W back in would be a huge risk.
Disclaimer: I'm not an Electrician, but I do have a degree in Electronic Engineering.
The solar is the same way, but with an auto cutoff.
What's new is cheap and ubiquitous micro-inverters. Before it wasn't worth putting a $800 inverter on a small 2-panel 600 or 800 installation. Now with micro inverters being so cheap, this tech becomes viable. And with loads so limited (less than a microwave) the regulation is equally light to allow this convenient plug-in solution.
On an AC circuit, all connections are duplex.
It needs to be paired with a transfer switch or it will backfeed.
Unfortunately it is a far too common thing for people to rig these things up themselves leading to all sorts of funny complications.
If you want to get an overview of the ecosystem, googling "Balkonkraftwerk" gives you the most relevant results.
I think this will be your biggest practical issue in newer US construction. Arc fault circuit interrupters are now code for any wiring in living spaces. They can be quite sensitive to weird switching loads (and sources). I was forced to swap an AFCI for a normal breaker in my last home. The power supply in my workstation triggered the detection heuristic in the AFCI about once a day. I could cause an outage on demand by running certain workloads.
The breakers do not prevent power flowing from an outlet back into the panel bus. They are thermal magnetic trip devices (99% of the time). The thermal is just a strip that when you get too much current for too long gets hot, expands, and trips the switch.
The magnetic part is a coil and too much current too quickly pulls it like a lever.
Nothing here will prevent “backflow” of electricity. It can’t because AC is always going both directions. It is reversing direction 50-60 times a second
The only thing you will hit is whether the power is on the same phase as your fridge. If not it’s going back to the grid.
There is also the problem of backfeeding, but this is more theoretical - even if you know to limit your power use, your neighbors won't and so your generator will trip its own breaker. Linemen are taught to either treat power lines like they are live, or to short them to ground - it can happen they don't do this and you kill a linemen, but still not as big a worry as it is made out.
They make generator "inlets" that sidestep all these problems when used correctly. Most common I've seen is a block so you can't have the inlet and the main breaker both on at once.
it is not theoretical from the POV of power company employees working on their lines. the power goes out, they go to fix the equipment or wiring, and if the inverters connected to the grid have not shutdown, there could be 10s of kW to even MWs being backfed into the system they are working on.
that's why in the US at least, grid-tied inverters are required to have protection against this. if they do not see power from the grid, they shutdown (and rather quickly).
Also, people have been back peeking the grid from their home generators for decades by now. Solar and inverters are a different variation of that attack, but it is nothing new. Any utility will have procedures because they can't guarantee that's not happening and we learned years ago.
I'm not saying it never happens, only that correct procedure already makes it not an issue
I realize this is a complete noob question but I'm still curious: with enough "backfeeders" could it not in theory be possible that the backeeders see each other's output and keep operating?
Say, a few houses at the end of the line, each with very little electricity consumption (no-one's at home), but with panels and inverters going full tilt, something like that?
(the specific case of very little consumption but panels and inverters going full tilt doesn't work as this would lead to the frequency rapidly increasing, exceeding inverter set points and the local grid collapsing with all the inverter tripping off. The danger scenario is closely matched load and generation, like a real grid)
Perhaps a more robust solution would be for the power company to install remote-switchable circuit breakers at various places of the grid. Use some sort of wireless IoT protocol to listen for "on/off" signals and to report back "I'm now on / I'm now off!". Then the power company can disconnect parts of the network by themselves, without trusting that every inverter, generator and battery will do the right thing.
If this weren't done, there would be risk of electricution to anyone working on wiring in the house or on the utility distribution network.
Skip to about 10 minutes into this video: https://practical.engineering/blog/2022/12/5/what-is-a-black...
Furthermore, the danger of backfeeding is if you do it in a power outage and you start to power your neighbors' houses. It'll overload your generator and create a hazardous situation for anyone working on the wires. (This is why you're supposed to install either a generator switch or interlock. I have one that only allows me to energize when my main breaker is turned off.)
It outputs at the same phase and frequency as the grid, and with a slightly higher voltage (think of a ball rolling down a slope from a higher voltage to lower voltage).
If the grid is down then it stops the inverter for a minimum safety period (some minutes iirc)
It can be quite safe to plug a generator into an outlet if you take precautions to properly island the system. I had an interlock on my breaker panel that would let me turn on a 50A backfeed breaker if my main breaker was switched off.
tl;dr Plug-in solar inverters must power off within a second if they stop detecting the grid's sine wave.
Generators have no such protection and will happily backfeed through the transformer outside your house to energize power lines. Line workers are careful, but there have been deaths. After hurricanes seems the most common based on a quick search.
So it's not a stupid question, indeed you should never plug a generator into an outlet. The double-ended "suicide cord" which allows you to do that has that name for a reason. (It can be fine to plug a generator into an inlet circuit, if the electrical panel has a proper interlock that physically forces disconnect from the utility before connecting the generator inlet.)
The better way (and legal way) to do this is to have a generator plug plug installed, this way when you switch over to generator your property is disconnected from the grid.
Obviously the inverters and pairing technology exist, but I don't know where to buy one retail.
welcome to the future
https://shop.sveasolar.de/category/ikea-shop
well old NA circuits are notoriously shittier and lower-amp-rated than in europe lol
i don't think it's a good argument against balcony solar but neither is that a good rebuttal
Don't call the US system "shittier". It is different, but that doesn't mean better or worse. Anytime the US needs more a little more power we put in 20 amp circuits for the same wattage. Anytime we need a lot more power we put in 240 volt circuits. Different, but it works just fine.
The power from the plug-in outlet is consumed by any devices connected on the same circuit first. Any extra flow through the electric panel’s bar connecting the circuits on the same 120V phase, where the devices on them use the extra next. Any excessive power flows back out of the meter on the 120V phase line on your service connection to the transformer at the street block. The transformer might feed it to your neighbors. In any case the transformer feed electricity to the other 120V phase line back into your service connection, the meter, the panel, the other split phase bar, the circuits on it, and the outlets on them. The devices on the other split phase circuits technically are not using the plug-in power directly.
Most modern meters measure electricity going in and out on both split phase lines as a whole, as a net amount, so the electricity consumed in the other split phase circuits is offset by the plug-in power. However some old meters add the outgoing electricity up as consumption so you are paying for the electricity fed into the grid. Call your utility company to make sure.
Also, unless you have a net metering agreement with your utility company, you won’t get paid for any excessive electricity fed back into the grid.
And on an unrelated note, it seems that hybrid power plants are becoming a talking point now and they seem to make a lot of sense. Like covering dams with solar panels saves on water, make PVs cooler/work more efficiently and you don’t need to worry about permits/building more grid connections because you can simply slow down hydro during daytime (and get along with grid following inverters just fine).
ERCOT frequencies have sagged when the grid was stressed.
Decentral battery units in substations, similar to what Tesla did in Australia many years ago. They can absorb or provide reactive power as well.
One constraint on these I've read is that if you have sources and sinks on the same circuit, you might overload the line without tripping the breaker at the box. If I'm understanding this correctly this has caused them to limit the power of plug-in solar to a fraction of what a single circuit could potentially carry.
While the power doesn't go out often, it is a big deal when it happens and so a backup is useful. I'm still fixing the damage from the last one - the sump pumps not running for an hour in a rain storm is expensive. Fortunately it wasn't a long outage, much longer and the fridge/freezer would be a problem. In cold weather the furnace is important to keep running. There are other essential things as well that my house cannot survive without. Beyond that I want my computers to keep running if possible.
My electricity supplier sends me a message nearly every week saying if I use less electricity during peak demand times then I get free power at weekends. https://octopus.energy/saving-sessions/
And it's the way it should always have been.
Sure, there are concerns with possibly melting house wiring, but they require some vanishingly unlikely situations to occur.
In other words, it can be useful even if it's not the most efficient way to do it. It only has to be more efficient than the status quo.
I don't have thd capital to build utility-scale solar. I do have the capital to install residential solar. My electricity is now cheaper.
I am thinking along the line of:
If you are going through all of that, there is not much benefit to plug-in solar instead of traditional.
So when the power goes out you unplug your fridge from the wall and plug it into the battery. In essence it operates like the standard camping battery/"solar generator", a la Jackery et al.
Having to plug in individual appliances seems to defeat the entire purpose. What happens if you’re away on holiday? Come home to a fridge full of trash? If power is back, do you even know how long the outage lasted? What about other devices that generally should have nonstop power or are typically hardwired? Sump pumps, HVAC equipment, water heaters, etc.
Where on the risk spectrum do you fall? I have a battery backup sump pump because I learned the hard way what happens when the power goes out and the generator doesn't start. If I fixed my generator though I'd have an automatic system that would run my sump pump, furnace, fridge, well, water heater, lights, computers, range, - and lots of other useful things as well so long as I'm careful about I run at the same time (anyone know how to fix a 1970s generator?)
Just how many natural disasters do Americans go through before realizing that?!
These disasters are rare though for any one person - a few happen every year, but it will be years between you personally seeing a disaster. That is why generators sell out when there is a storm: even if you have a generator odds are it is rusted and won't work. It is a waste of money to buy a generator before you need it.
For example Duke is for profit here in Florida, and charges about 25% more per KWH than OUC that is a public utility.
This leads to pricing where on one street your power bill is $250, but one street over its $200, often coming from the exact same power plant.
FPL is also for profit, and is cheaper than OUC.
1st 1000kwh with FPL are $0.11461/kwh Above that is $0.13461/kwh with a base customer charge of $10.52
1st 1000kwh with OUC are $0.1155/kwh Above that is $0.1405 with a base customer charge of $18.50/mo
Total cost with FPL for 1000kwh for the month before state and local tax is $125.13
With OUC it would be $134.
https://www.ouc.com/wp-content/uploads/2025/09/2025_10-OUC-E...
https://www.fpl.com/content/dam/fplgp/us/en/rates/pdf/reside...
The biggest factor Id say is FPL has significant amounts of solar and nuclear generation.
https://www.fpl.com/content/dam/fplgp/us/en/news/2025/fpl-ne...
18.8% Nuclear and 8.4% solar (more than double the national average!)
OUC on the other hand has less than 3% Nuclear (generated / purchased from FPLs plant on Hutchinson Islans!) and <6% solar, with a massive 24% still being generated by coal! (FPL demolished their last coal plant ~8 years ago in Indiantown, I watched it live!)
https://www.floridapsc.com/pscfiles/website-files/PDF/Utilit...
So while FPL is technically for profit and OUC is not... FPL is cheaper and greener than OUC.
I say this as a long time Florida resident who remembers when FPL truly sucked in many ways. They’ve, demonstrably, put in effort to make electricity greener and cheaper here in FL. (Even with all of their efforts against home solar).
This is a nice grassroots technology that lets motivated individuals take action.
And since transmission cost is typically bundled with the energy cost, it means the final retail energy price has to go up to cover the transmission cost.
Why? Overall transmission cost are defined by highest possible consumption, and solar panels have practically no effect on that parameter.
Utility companies are not incentivized to lower prices because it means less money for them. Do you remember when power companies told people to conserve power and then people successfully did this? And then they raised rates because they weren't making enough money? This happens in California ALL THE TIME. I've lived here 30 years in Silicon Valley and it's the biggest scam that no one talks about. It happens with electricity and water. With water its even more egregious because they told us to conserve water because of the "drought" but once the drought was over, they raised rates because people weren't using enough water. My connection fee to water is over $100/month without spending a drop of water. That's why I stopped conserving water and water my lawn every single day because it turns out that my water costs are only about 1/3 of the actual water bill costs so fuck it!
It's the same playbook over and over again, there's no incentive to lower rates at all because it's an easy way to make money over an entire population of tens of millions of people.
Now PG&E is fighting to charge solar panel owners $100+/month just for the privilege of being connected to the grid. That would make having solar panels even more expensive than not having solar panels which is utter hypocrisy but no one seems to care or point this out. It's a complete and utter scam.
EDIT: I forgot to mention last year the rates were $0.37-0.45 per kWh, until this year when they implemented a base fee of $25/month, so they lowered it to $0.33-0.45/kWh. Rates in Nevada are 1/4 of that.
2015: $0.17-0.33 per kWh
2020: $0.24-0.38 per kWh
so prices have more than doubled in 10 years. Fucking criminals.
The day after the system goes live, they'll probably announce flat rates for any time of day, just to f' with me. :(
I am a staunch DIY serial entrepreneur techie that has used my grey goo to build and sell a few companies and my time now is spent similar to yours although using a different application of physics. I too am motivated, just as you are, in my efforts to apply what I know to further reduce my energy costs which will not stop rising for quite some time.
You really made my day with this post and I hope we can find more folks like ourselves from your share because in time 'dogfooding' new ideas at home will lead to new applicable discoveries for all.
Stay Healthy!
https://www.youtube.com/watch?v=IA15VkLlx-w
Its like a large freezer gel pack.
Enjoy.
Every system like yours works to flatten the prices, but it looks like a pretty big swing between peak and off peak pricing today, so it'll probably be a while before flat pricing again.
The more stable you think the future will be, the more you want to capture the efficiency of central power.
I'm not saying you're necessarily wrong, I just don't see society taking that measure until it's either 1) cheaper, or 2) the threat moves from being just a threat to reality.
Completely agree. But I'm already there. Large scale economic disruption has just started. For that to remain peaceful over the next few decades would be a miracle. So we should plan for disruption, for which energy decentralization is a keystone, and the technology to make it practical is here.
California has a 600 MW Virtual Power Plant composed of Tesla Powerwall batteries in 85k homes. Central control of distributed generation removes a lot of inefficiencies. Household excess is available to the whole system.
https://www.entsoe.eu/news/2026/03/20/entso-e-publishes-expe...
There are probably only a handful of backbone transmission routes which serve tens of millions of people. These are isolated and unprotected and could likely be disabled with a loaded truck plowing into a critical piece of infrastructure.
It does not take much to bring down electricity distribution.
With fixed solar installs you're likely to find some kind of switch or labeled breaker to disconnect. The system is designed with a central "power in" that's (hopefully) obvious/proximate when you're standing in the breaker room.
These things could be injecting power anywhere, so you need to know they're there (which may be less apparent than roof/field panels) and go around and pull the plug(s). Relevant to electricians, firefighters, etc.
Your circuit breaker protects your circuits by putting all the load (eg your microwave) on one side, and your supply (mains power) on the other. If too much load is present, the circuit breaker trips.
However, plugin solar puts invisible supply on the load side, which your circuit breaker cannot see. Let's make an absurd example so you can see what the problem is, then scale it back.
Imagine someone buys 5 panels that can each supply 5amps. They plug them into outlets on a 40 amp circuit. They then proceed to run their toaster, microwave, vacuum, and hair dryer. They can draw 65 amps through the wires before the circuit breaker trips. (40 from mains, 25 from the panels)
Let's say they had a good electrician who installed 6AWG wiring on that circuit, which is rated for 50 amps. The circuit breaker used to trip at 40, so no problem. But now up to 65 can go across the wires and suddenly you are exceeding rating for wires.
Now you might say, "most of these are 3.5 watts, and they clearly say don't use more than one". But I say that's a "good intentions solution". We should make it mechanically impossible to do the wrong thing. Maybe these panels could try to communicate over the electrical wires, and if they detect a signal from another panel they should self limit. Maybe we need to rethink circuit panel design. But as it stands people will absolutely buy one of these, decide they love it, and then buy 4 more.
I think this is probably fine, since UK circuits are typically 20A. Apart from fault current (which would have to be line to line, since line to ground would trip the RCD), it's quite hard to end up with more than 20A of stuff plugged into regular sockets unless you're overinvested in portable heaters. All the big stuff - cookers, heat pumps, showers - is on separate breakers from the sockets.
In the original example, RCD/circuit protection is regulated on the _property_ side, e.g UK has EICR for electrical install. Once its done for a property, its good until next inspection (in theory)
This moves the protection to the _appliance_ , which while it needs to meet certification, is much harder to police a consumer electronic device, than a physical unmovable premise.
I think these are great, but there will inevitably be devices that don't implement the spec correctly that still get sold to willful or unwillful consumers that result in danger to everyone.
They’d also probably depend on a power signal to frequency match.